Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F2.19
Deceleration time
4
0.1
○
F2.20
Jog operation
frequency
0.10
~
50.00Hz
0.01Hz
5.00Hz
○
F2.21
Jog interval time 0.0
~
100.0s
0.1s
0.0s
○
F2.22
Jog acceleration
time
0.1
~
60.0s
0.1
Model
determined
○
F2.23
Jog deceleration
time
0.1
~
60.0s
0.1
○
F2.24
Skip frequency 1 0.00
~
550.0Hz
0.01Hz
0.00Hz
×
F2.25
Skip frequency 1
range
0.00
~
30.00Hz
0.01Hz
0.00Hz
×
F2.26
Skip frequency 2 0.00
~
550.0Hz
0.01Hz
0.00Hz
×
F2.27
Skip frequency 2
range
0.00
~
30.00Hz
0.01Hz
0.00Hz
×
F2.28
Skip frequency 3 0.00
~
550.0Hz
0.01Hz
0.00Hz
×
F2.29
Skip frequency 3
range
0.00
~
30.00Hz
0.01Hz
0.00Hz
×
F2.30
Anti-reverse
selection
0
:
Reverse allowed
1
:
Reverse prohibited
1
0
×
F2.31
Forward and
reverse dead time
0
~
3600s
0.1s
0.0s
×
F2.32
Zero frequency
operation allows
selection
0
:
Zero frequency allows
operation
1
:
zero frequency forbid
operration
1
0
×
Motor parameter F3 group
F3.00
Motor poles
2
~
14
2
4
×
F3.01
Rated power
0.4
~
999.9kW
0.1kW
Models
determined
×
F3.02
Rated current
0.1
~
999.9A
0.1A
×
F3.03
Rated speed
1rpm~9999rpm
1rpm
1470rpm
×
F3.04
Rated frequency 1.00
~
550.00Hz
0.01Hz
Models
determined
○