GT200 series general purpose inverter instruction manual
then the greater of braking resistor power and smaller of resistance value.Table 1-5,1-6 is
recommended according to general applications(Breaking Utilization rate FC.01 is 10%)
Table 1-5 Select table of braking resistor (380V)
Model No.
Applicable
motor Power
(
KW
)
Resistor
Resistance (Ω)
Resistor Power
(W)
GT200-4T0007G/-
0.75
≥500
100
GT200-4T0015G/-
1.5
≥300
200
GT200-4T0022G/-
2.2
≥200
200
GT200-4T0040G/4T0055P
3.0
≥200
300
GT200-4T0055G/4T0075P
5.5
≥80
750
GT200-4T0075G/4T0110P
7.5
≥50
1100
GT200-4T0110G/4T0150P
11
≥50
1500
GT200-4T0150G/4T0185P
15
≥45
1800
GT200-4T0185G/4T0220P
18.5
≥45
2200
GT200-4T0220G/4T0300P
22
≥24
3000
Table 1-6
Select table of braking resistor (220V)
Model No.
Applicable
motor Power
(
KW
)
Resistor
Resi
stance (Ω)
Resistor Power
(W)
GT200-2S0007G
0.75
≥150
100
GT200-2S0015G
1.5
≥100
200
GT200-2S0022G
2.2
≥75
300
12