1.1
SPECIFICATIONS :
Operation Voltage: 115 / 230V AC
Supply Voltage Fluctuation: Not to 10% of the operating voltage
Supply Frequency 50 - 60Hz
Max Power Consumption 20 VA
Operating Temperature 0 'C - 45 'C 32 'F - 113 'F
Operating Relative Humidity <=95% (45 'C + 2 'C )
Storage Temperature -40 'C - 55 'C -40 'F - 131 'F
Storage Relative Humidity <=95% (45 'C + 2 'C)
Inputs: Depend on model, 2, 3 or 4 Linear Transducers
** we reserve the right to change the specifications as listed in above without any prior notice. **
2.1
MOUNTING
Select the location of the installation with due regard of safety and ease of operation. Keep the DRO
away of moving parts and coolant spray. To ensure correct operation of the DRO , make sure that the
DRO is correct grounding. Grounding diagram is as shown in SAFETY NOTICE.
The DRO can be mounted on 4 different arm stand brackets as per detailed on the Optional Accessories List.
As shown in Figure 2.1:
Figure 2.1 Mounting of the DRO
II
SPECIFICATIONS
MOUNTING & INSTALLATION
The DRO have been to conforms to relevant standards for electromagnetic compatibility ( EMC ) as detailed
below.
IEC 61000-6-2 :
Electromagnetic compatibility, Generic Immunity Standard - Industrial Environment.
IEC 61000-6-4 :
Electromagnetic compatibility, Generic Emission Standard - Industrial Environment.
EN 61000-6-2 :
Electromagnetic compatibility, Generic Immunity Standard - Industrial Environment.
EN 61000-6-4 :
Electromagnetic compatibility, Generic Emission Standard - Industrial Environment.
GB/T 17799-2 :
Electromagnetic compatibility, Generic Immunity Standard - Industrial Environment.
GB/T 17799-4 :
Electromagnetic compatibility, Generic Emission Standard - Industrial Environment.
EMC compliance
Double Joint
Arm Stand
( 3.BR.05.0034 )
3.BR.05.0031
Lathe Top Headstock
Arm Stand
(
)
Standard Lathe
Headstock Arm Stand
(
)
3.BR.05.0026
Standard Single Joint
Arm Stand
( 3.BR.05.0001 )
Summary of Contents for ES-12
Page 8: ...1 Basic Fucntions Basic Functions BASIC...
Page 15: ...8 Built in Calculator Calculator...
Page 27: ...20 REF datum memory...
Page 31: ...24 LHOLE tool positioning for the Line Holes...
Page 35: ...28 INCL Inclined angle tool positioning...
Page 40: ...33 PCD tool positioning for Pitch Circle Diameter...
Page 45: ...R R R 38 tool positioning for ARC machining...
Page 63: ...R R R 56 Simplified R function...
Page 73: ...66 Shrinkage Calculation L L X 1 005...
Page 91: ...Parameter Setup B 1 SET UP...