To access the option modules, first pull the instrument from the housing.
a. Detach the main boards by lifting first the upper, and lower mounting struts.
b. Plug the required option modules into the correct connectors, as shown below.
c. Locate the module tongues in the corresponding slot on the opposite board.
d. Hold the Power and Input boards together while relocating on their mountings.
e. Push the boards forward to ensure correct connection to the Display board.
f. Replace the instrument by aligning the boards with the guides in the housing,
then slowly push the instrument back into position.
Note: Option modules are automatically detected at power up.
Main Board Connectors
Power Supply Board
Transformer Colour Code
100-240V (Yellow)
24-48V(Blue)
Option 3 Slot
Connector PL4B
Option Slot A
Connectors PL5 & PL6
Option 1 Slot
Connectors PL7 & PL8
PC Configurator Socket SK1
Option 2 Slot
Connectors PL4A
Display Board
Connections
Universal
Input Board
Note:
Plastic pegs
prevent fitting of older
nonreinforced single
relay modules – remove