Trend View graphs PV; or Max/Min PV between samples, plus active alarms. Trend Scale Values 

adjust automatically to visible data (between 2 to 100% of the input span). Sample intervals are 

set in Display Configuration. Pressing     or     moves the Cursor Line back through the last 240 data 

points. 

Note: Data is not retained at power down or the Sample Interval is changed.

Over/Under Range & Input Fail Indications

If the process or auxiliary inputs are >5% above or below the scale max/min, their displayed value is 

replaced with the word “

HIGH

” or “

LOW

”. If a signal break is detected, their value is replaced with 

OPEN

” and an uncalibrated input is replaced by “

ERROR

”. In OPEN or ERROR conditions, the

Control

 Outputs go to the pre-set power value (see Control Config).

Caution:

 Correct the problem before continuing normal operation.

6. Serial Communications

Set Ethernet option IP address with supplied software for networks without DHCP.

Refer to the User guide (from your supplier) for help with communications.

7. Strain Gauge Calibration Mode

Press the     +     to enter calibration mode from any location for quick access (see Strain Gauge 

Calibration in Configuration Mode)Only applicable when Sensor input type is set to Strain Gauge.

8. Auto/Manual Key Press

Press the     +     to change the control mode. When pressing these keys it will put the unit into 

manual mode if already in Auto and move back to the main operator screen. Pressing while in 

Manual will put the controller into Auto control and back to Main operator screen. 

Use with Caution

9. Pressure Control Description

This mode is entered at power on, or accessed from the Main Menu. If required, all Operation Mode 

parameters can be made read only (see Display Configuration).

Note: Configuration must be completed before starting normal operations.

Output value indication: 

  

Selectable between the following modes:

 

 

- range 0/100.0%.

 

 

- scalable with two proper values for RPM indication. (Same value as above only two  

 

 

  point scaled to give RPM)

 

 

In automatic mode either mode is available (not at the same time)

 

 

In manual mode a parameter is provided to select the first or second method of 

 

 

indication.

Summary of Contents for ATC990

Page 1: ...From lab to production providing a window into the process 1 www dynisco com Rev n a P N n a ECO n a Dynisco ATC990 Graphical 1 4 DIN Process Controller Concise Product Manual Operating Manual...

Page 2: ...allation safety must be observed e g US National Electrical Code NEC and or Canadian Electrical Code Impairment of protection will occur if the product is used in a manner not specified by the manufac...

Page 3: ...ntings e Push the boards forward to ensure correct connection to the Display board f Replace the instrument by aligning the boards with the guides in the housing then slowly push the instrument back i...

Page 4: ...he instrument housing towards rear face of mounting panel until the tongues engage in ratchets and instrument is clamped in position Hold instrument firmly in position apply pressure to bezel only CAU...

Page 5: ...y marked All connections to the device must be made through a spade format or similar connection with connection to the spade terminal touching both the insulation and conductor material Use a standar...

Page 6: ...lution Impedance 10M resistive except DC mA 5 and V 47k Temp Stability Error 0 01 of span per C change in ambient temperature Supply Variation Supply voltage influence negligible within supply limits...

Page 7: ...to 2320 C 32 to 4208 F D 0 to 2315 C 32 to 4199 F E 240 to 1000 C 400 to 1832 F J 200 to 1200 C 328 to 2192 F K 240 to 1373 C 400 to 2503 F L 0 to 762 C 32 to 1402 F N 0 to 1399 C 32 to 2551 F PtRh 20...

Page 8: ...Scalable from 99999 to 100000 Decimal point selectable from 0 to 3 places but limited to 5 display digits e g 9999 9 Up to 15 scaling values can be defined anywhere between 0 1 and 100 of input Open c...

Page 9: ...e relay modules Remove the peg to fit dual relays all dual relay modules have reinforced isolation Single Relay Type Rating Single pole double throw SPDT 2A resistive at 120 240VAC Lifetime 500 000 op...

Page 10: ...8 data bits and 1 stop bit Odd even or no parity Isolation 240V reinforced safety isolation from all inputs and outputs Ethernet Connection Locates in Option Slot A Connection via RJ45 connector on to...

Page 11: ...cleaning Display Display Type 160 x 80 pixel monochrome graphic LCD with a dual colour red green backlight Display Area 66 54mm W x 37 42mm H Display Characters 0 to 9 a to z A to Z plus and _ Trend...

Page 12: ...n also be run from the Main Menu It exits to Operation Mode once completed Start Up Errors These messages indicate that a hardware or configuration an error has occurred Caution Do not continue with t...

Page 13: ...aved time At start of phase Delta reset timeout generator 4 5 saved time Err limit The process reaction goes into the wrong direction after setting the controller output pulse Err Parameter The estima...

Page 14: ...without DHCP Refer to the User guide from your supplier for help with communications 7 Strain Gauge Calibration Mode Press the to enter calibration mode from any location for quick access see Strain G...

Page 15: ...tune step is set too high it will create an overshoot and therefore needs to be reduced The pre tune step power is added to manual power and displayed to the user but is not changeable The expected ra...

Page 16: ...Max actual controller output Standby Active Limit The freezing of the output of the controller will last for a time specified by the Pressure stand by recovery time parameter If the parameter Pressure...

Page 17: ...ferential Input only applicable if Input2 card fitted and set to non temperature Primary Control Action Reverse or Direct acting Primary Secondary proportional band Integral Time Enter Value of requir...

Page 18: ...m through which the signal must pass before alarm deactivates Signal change Alarm n Min Minimum time the rate of PV change must be above the alarm threshold for a Rate Of Change Alarm to change state...

Page 19: ...e day of week used by the internal clock Recorder versions only Set Time w Sets the internal clock Time In hh mm ss Hours Minutes Seconds format Recorder versions only Display Configuration Enable Cus...

Page 20: ...t point values Alarm Status Active inactive status of all configured Alarms Trend View s A trend graph of PV1 PV2 or Differential or the Max Min value of the PV between samples Any active alarm s are...

Page 21: ...s pfl for profiles is added automatically Caution Existing files folders with the same name will be over written Writing Configuration File The file is being written Caution Do not disconnect USB devi...

Page 22: ...ations section for details Engineering Units w Select display units from C F K bar RH pH psi or none Decimal Point Position w Display resolution with 0 1 2 or 3 decimal places Temperature inputs are l...

Page 23: ...h you conduct the High end calibration and required offset for calibration Calibration reminder Calibration reminder Enable or Disable Calibration reminder Calibration Reminder Date Set the date that...

Reviews: