SD-BOX INSTRUCTION MANUAL, CODE: DYN 81.01.00
Date: 03/03/2020
Version 00
- 24 -
Test 5
– Check wait time after arriving at a floor (default is 10 minutes):
•
Press the “RESET” button.
•
Make a call and wait longer than the programmed time (which by default is 10 minutes).
•
Check the LEDs are in the status indicated in the following table:
LED
On
Off
POWER
X
STAND-BY
X
BATTERY CHARGING
X (if the battery is charging)
X (if the battery is charged)
BATTERY FAILURE
X (if the battery is discharged
or not connected)
X (if the battery is charged
and connected)
FAILURE CONFIGURATION
X (if configured to show
system fault at output)
X (if configured to show coil
status at output)
MANUAL RESCUE/BYPASS
X
MANUAL TRIPPING
X
UCM DETECTED
X
DOORS
X (while waiting, the doors
can either be open or closed)
X (while waiting, the doors
can either be open or closed)
MOTOR
X
LEVEL1
X
LEVEL2
X
INDUCTOR/
μ
SWITCH
X
COIL STATUS
X
•
Make a call.
•
Check the overspeed governor is unlocked before the car moves and the safety gear is
disengaged.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/