SD-BOX INSTRUCTION MANUAL, CODE: DYN 81.01.00
Date: 03/03/2020
Version 00
- 17 -
5.3.
ELECTRICAL DIAGRAMS
1 OUTPUT. Normally open (NO) for fault indicator/coil status. This contact is closed if there is
a fault or the coil is activated.
2 OUTPUT. Normally closed (NC) for fault indicator/coil status. This contact is open if there is
a fault or the coil is activated.
3 OUTPUT. Common for fault indicator.
4 OUTPUT. SAFETY LINE: Common safety contact to connect to safety line.
5 No connection.
6 OUTPUT. SAFETY LINE: Normally open contact to connect to safety line.
7-19 No connection.
20 INPUT. External reset. 0 V
21 INPUT. External reset, 24 V. If there is voltage, the reset action is performed.
22 INPUT. Level 1. 0 V
23 INPUT. Level 1. 24 V.
24 INPUT. Level 2. 0 V
25 INPUT. Level 2. 24 V.
26 INPUT. Remote manual rescue, 0 V.
27 INPUT. Remote manual rescue, 24 V. If there is voltage for more than 3 seconds, the manual
or bypass rescue action is performed.
28-31 No connection.
32 INPUT. 24 V
DC
power supply.
33 INPUT. 0 V power supply.
34 INPUT. Bat
35 INPUT. Batteries -
36 No connection.
37 No connection.
38 OUTPUT. Inductive sensor, 0 V power supply.
39 INPUT. Inductive sensor, Detection.
40 OUTPUT. Inductive sensor, 24 V
DC
power supply.
41 No connection.
42 OUTPUT. Coil, 24 V
DC
43 OUTPUT. Coil, 0 V
DC
44-48 No connection.
49 INPUT. Doors, 0 V
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/
Summary of Contents for SD-BOX
Page 2: ......