SD-BOX INSTRUCTION MANUAL, CODE: DYN 81.01.00
Date: 03/03/2020
Version 00
- 22 -
Test 2
- Doors closing and normal travel operation
•
Press the “RESET” button.
•
Make a call.
•
Check the LEDs are in the status indicated in the following table during the travel between
floors:
LED
On
Off
POWER
X
STAND-BY
X
BATTERY CHARGING
X (if the battery is charging)
X (if the battery is charged)
BATTERY FAILURE
X (if the battery is discharged
or not connected)
X (if the battery is charged
and connected)
FAILURE CONFIGURATION
X (if configured to show
system fault at output)
X (if configured to show coil
status at output)
MANUAL RESCUE/BYPASS
X
MANUAL TRIPPING
X
UCM DETECTED
X
DOORS
X
MOTOR
X
LEVEL1
Flashes when passing
through each level during the
travel
X
LEVEL2
Flashes when passing
through each level during the
travel
X
INDUCTOR/
μ
SWITCH
X
COIL STATUS
X
Test 3
- Checking the battery charge
This test should be carried out only if batteries are used as an auxiliary power source.
•
Press the “RESET” button.
•
Check the battery is properly connected to the corresponding terminals.
•
Check that the “BATTERY CHARGING” LED is on (or off if it is fully charged) and the
“BATTERY FAILURE” LED is off. If the “BATTERY FAILURE” LED is on:
o
Note down the voltage of the batteries.
o
Leave for a few minutes.
o
If the "BATTERY FAILURE" LED does not turn off during this time, check the battery
voltage: this must be higher than previously noted.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/
Summary of Contents for SD-BOX