SD-BOX INSTRUCTION MANUAL, CODE: DYN 81.01.00
Date: 03/03/2020
Version 00
- 23 -
Test 4
- Performing the rescue operation without power in the lift
•
Press the “RESET” button.
•
Cut the power supply to the lift. This can be done at the floor level; it does not need to be
done outside of the level.
•
Check the “BATTERY FAILURE” is not lit. If it is, perform Test 3, “Checking the battery
charge”.
•
Wait 4 seconds for the overspeed governor to be locked.
•
Press the “MANUAL RESCUE/BYPASS” button for more than 3 seconds.
•
Check the overspeed governor is unlocked.
•
Check the SD-BOX beeps intermittently during the “MANUAL RESCUE/BYPASS” mode.
•
Check the LEDs are in the status indicated in the following table:
LED
On
Off
POWER
X
STAND-BY
X
BATTERY CHARGING
X (if the battery is charging)
X (if the battery is charged)
BATTERY FAILURE
X (if the battery is discharged
or not connected)
X (if the battery is charged
and connected)
FAILURE CONFIGURATION
X (if configured to show
system fault at output)
X (if configured to show coil
status at output)
MANUAL RESCUE/BYPASS
X
MANUAL TRIPPING
X
UCM DETECTED
X
DOORS
X
MOTOR
X
LEVEL1
X
LEVEL2
X
INDUCTOR/
μ
SWITCH
X
COIL STATUS
X
•
Press the “MANUAL RESCUE/BYPASS” button.
•
Check the intermittent beep disappears.
•
Reconnect the lift power supply.
•
Check the SD-BOX recovers its normal operating status.
The maximum time for the “MANUAL RESCUE/BYPASS” status with battery power is 10 minutes.
After this time, the SD-BOX automatically returns to a state of rest.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/
Summary of Contents for SD-BOX