18
CC 501/501C O501EN3
The amplitude setting may not be altered while
the vibration motor is running. Wait until vibra-
tion stops before resetting.
Set the vibration selector (27) to MAN.
Move the forward/reverse lever forward or back.
Switch the vibration ON with the button (23) on the
forward/reverse lever. Both drums are activated.
The roller can be run with vibration in one drum only by
setting the respective amplitude selector to the O
position.
Wait until the roller is moving before switching
on the vibration.
KÖRNING/VIBRERING
24
29 28 27
23
DRIVING/VIBRATION
Fig. 17 Amplitude setting
23. Vibration ON/OFF
27. Vibration setting
MAN-O-AUT
23
27
Vibration may not be applied while the roller is
stationary.
1. Set normal operating speed of the engine (2200 rpm)
so that maximum rate of vibration 2700 VPM (45 Hz) is
obtained.
2. Set the desired amplitude (high or low) on the front
and rear drum with (28) and (29). Set the vibration
selector (27) to MAN or AUT.
In AUT mode: Vibration is automatically switched ON
and OFF by the forward/reverse lever
during operation.
In MAN mode: Vibration is switched ON and OFF with
the button (23) on the forward/reverse
lever.
Fig. 16 Instrument panel
23. Vibration ON/OFF
24. Forward/Reverse lever
27. Vibration switch (MAN/AUT)
28. Amplitude selector (High/Low)
(CC 501 only)
Amplitude selector, front (High/Low)
29. Amplitude selector, rear (High/Low)
Manual vibration
Summary of Contents for CC 501