No. 60025, Issue 5. January 1999
8 Programming
33
If set to ‘no’, the wheelchair will drive normally with no CLAM (or
TAM) attached. Providing that all CLAM (or TAM) parameters have
been programmed, this is a useful factory setting. It allows a CLAM (or
TAM) to be added later to wheelchair systems that do not have one fitted,
without the HHP or Wizard.
CLAM Slowdown
Range:
0 - 100%
Default:
20
OEM Access: Read / Write
Dealer Access: Read only
Set to a required percentage of maximum wheelchair speed allowed when
the slow input is active. For this facility to be used, the hardware of the
wheelchair must be arranged as described in the Slow / Stop section in
the Installation Manual of the DX Module driving the actuators, e.g.
CLAM or TAM.
Actuator 1 Enable
State:
yes / no
Default:
no
OEM Access: Read / Write
Dealer Access: Read only
If set to ‘Yes’, Actuator 1 is enabled and can be selected by pressing the
Actuator 1 select switch on the Dolphin or ARC (Actuator Remote
Control) type module.
If set to ‘no’, there will be no response to the Dolphin Actuator switch.
Actuator buttons can be disabled if there are less actuators fitted to the
wheelchair than the number of actuator switches on the Remote.
Actuator 2 Enable
State:
yes / no
Default:
no
to
Actuator 5 Enable
OEM Access: Read / Write
Dealer Access: Read only
As described for Actuator 1 Enable. Refer to the Installation Manual for