No. 60025, Issue 5. January 1999
Installation and Testing 6
14
Testing
Ensure that all DX Modules used in your DX System have been installed as
specified in their Installation Manuals. The Dolphin needs to be correctly
programmed for the appropriate wheelchair prior to testing.
A DX Remote contains the complete wheelchair system set up, from which all
DX Modules download their relevant information when the DX System is first
turned on. Refer to the later Auto Download section.
Powering Up Method
Power up the Dolphin by pressing the On/Off switch.
Power Up Response
The power up response for the Dolphin is :
!
The System Status LED will come on steady.
Note :
The first time the Dolphin is turned on, the System Status LED will
flash a fault. This is because the Dolphin must download its information to the
DX Power Module . Turn the Dolphin off then on to clear this fault. Refer to
the later Auto Download section.
!
At least one of the LEDs on the Battery gauge will be on.
!
The Mode display will indicate a number from 1 - 5.
DX Dolphin Check Sequence
Perform the following Dolphin check sequence :
1. Press the On/Off switch again and check the Power LED turns off. Press
it again to turn it on.
2. Press the Drive Program select switch a number of times. Check that the
display changes as expected.
3. Check all Lighting Buttons operate correctly.
4. Check the Key Lock system operates correctly.
5. Perform the remainder of the tests as outlined in the Testing sections of the
Installation Manuals of all other DX Modules used on the wheelchair.