No. 60025, Issue 5. January 1999
Programming 8
32
Reverse RJM Joystick
State:
normal / reverse
Default:
normal
OEM Access: Read / Write
Dealer Access: Read / Write
Reverses the direction (left / right) of the RJM joystick.
If set to 'Norm', left and right joystick deflection causes a left and right
turn, respectively
If set to ‘Yes’, left and right joystick deflection produces the opposite
effect. Forward and reverse are not affected. Used if the RJM is mounted
in an other than standard orientation in order to maintain normal joystick
sense.
RJM Dual Decode
State:
single / dual
Default:
dual
OEM Access: Read only
Dealer Access: Not available
Set to ‘dual’ if the RJM is connected and has a six wire joystick with
mirror signals. Normally set to ‘dual’ for safety requirements. (View only,
not adjustable by OEM).
Actuator Parameters
Refer to the Installation Manual for the DX Module driving the actuators,
e.g. TAM, CLAM, ARC5.
CLAM Enable *
State:
yes / no
Default:
no
OEM Access: Read / Write
Dealer Access: Read / Write
Must be set to ‘yes’ for CLAM or TAM operation.
CLAM is critical
State:
yes / no
Default:
no
OEM Access: Read / Write
Dealer Access: Read only
If set to ‘yes’, a CLAM or TAM must be present in the system and
operating normally. The loss or lack of communications between the
CLAM (or TAM) and the Dolphin will cause the wheelchair to stop, and
a Flash Code 1 to be displayed by the Remote.