Chapter 4: Programming the Rhino2
64
4.4.1.3
Swap Throttle Direction
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Swap Throttle Direction
No / Yes
No
This parameter is normally only used when
(4.4.2.1) is set to 'Wig-wag'.
For single-ended and uni-polar throttles, use a Forward/Reverse switch instead (see 4.4.9.1). If
this parameter is used in conjunction with a Forward/Reverse switch, then it will invert the
polarity of the Forward/ Reverse switch.
Yes
- The polarity of the throttle is reversed. Moving the throttle in the direction that
normally causes forward movement now results in reverse movement while the
reverse buzzer beeps. Typically used for left-handed operation.
No
- The polarity of the throttle is normal. Typically used for right-handed operation.
Notes:
parameter (4.4.5.4) also reverses the direction of the scooter,
but it does not swap the behaviour of the reversing buzzer or the speed limit
parameters. If
is set to 'Yes', the reversing buzzer will beep when the
scooter moves
forward
, and the forward speed will be limited by the
Maximum
Reverse Speed
parameter. For this reason, do not use
handed operation. Use
Swap Throttle Direction
instead.
4.4.1.4
Enable Beeper
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Enable Beeper
No / Yes
Yes
Yes
- The beeper will beep according to the settings of
and
No
- All beeper functions are disabled.
4.4.1.5
Flash Code Beeper
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Flash Code Beeper
No / Yes
No
This parameter is only used when
Enable Beeper
has the value 'Yes'.
Yes
- If a flash code is shown on the Status LED, the buzzer beeps the same number of
beeps as the flash code number.
No
- The buzzer does not beep during a fault.