Installation
12
© 2012 DynaGen Technologies Inc.
TOUGH Series User Manual
2.5
Relay Pak (RP100)
The Relay Pak (RP100) can be used to control DC devices. Be sure to select relays based on your
system voltage (12 or 24V). Listed below are the wiring connections and their functions.
TERMINAL
FUNCTION
DESCRIPTION
J1-2
J1-5
-Battery
This connection provides a ground return line from the RP100 to
the controller.
J1-6
J1-4
J1-3
J1-1
Relay A (Coil)
Relay B (Coil)
Relay C (Coil)
Relay D (Coil)
Activated by applying 12 / 24V to the terminal. These are
intended to be connection to switched outputs on the controller.
J2
J5
J4
J7
Relay A (Contact)
Relay B (Contact)
Relay C (Contact)
Relay D (Contact)
Connect to high current auxiliary devices. Wire gauge is
dependent upon current requirements.
Pilot Duty Rating: 5.83A per relay
Resistive Rating: 10A per relay (40A Momentary)
J3
A/C Common
(Contact)
Relays A and C share a common contact point. Connect this
terminal to +Battery or -Battery. Wire gauge is dependent upon
amperage requirements.
J6
B/D Common
(Contact)
Relays B and D share a common contact point. Connect this
terminal to +Battery or -Battery. Wire gauge is dependent upon
amperage requirements.
The following is a sample wiring diagram using the RP100. Keep in mind that the wires from connector
J1 are connected to the controllers switched outputs and ground.