MAINS OPERATION & RESULTING POWER AMP TEMPERATURES
The following tables are useful in determining power supply and cabling requirements.
The power drawn from the mains network is converted into acoustic output to feed the connected
loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred
to as leakage power or dissipation (
P
d
). The amount of heat resulting from power dissipation might
remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table
is meant as auxiliary means for calculating temperatures inside of rack-shelf systems/cabinets and the
ventilation efforts necessary.
The column “Pd” lists the leakage power in relation to different operational states. The column “BTU/
hr” shows the
dispensed heat amount per hour
.
MAINS OPERATION & RESULTING
LX2200
U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
Pd
(5)
[W]
BTU/hr
(1)
idle
230
0.8
80
-
80
273
Max. Output Power @ 8Ω
(1)
230
11.0
1780
2 x 600
580
1980
Max. Output Power @ 4Ω
(1)
230
19.5
3240
2 x 1100
1040
3549
1/3 Max. Output Power @ 4Ω
(1)
230
11.3
1740
2 x 366
1008
3439
1/8 Max. Output Power @ 4Ω
(1)
230
4.6
640
2 x 137
366
1249
1/8 Max. Output Power @ 4Ω
(2)
230
6.0
850
2 x 137
576
1965
1/8 Max. Output Power @ 4Ω
(2),(4)
253
6.1
950
2 x 166
618
2109
Normal Mode (-10dB) @ 4Ω
(1)
230
4.2
580
2 x 110
360
1230
Rated Output Power (0dB) @ 4Ω
(1)
230
17.6
2860
2 x 900
1060
3617
Alert (Alarm) Mode (-3dB) @ 4Ω
(1)
230
12.6
1980
2 x 450
1080
3685
Max. Output Power @ 2Ω
(1)
230
30.3
5280
2 x 1600
2080
7100
1/8 Max. Output Power @ 2Ω
(1)
230
7.0
1030
2 x 200
630
2150
1/8 Max. Output Power @ 2Ω
(2)
230
8.4
1250
2 x 200
850
2900
(1) Sine Modulation (1kHz) (2) Pink-Noise according EN60065 (3) 1BTU = 1055.06J = 1055.06Ws
(4) 10% Mains Over Voltage (5) Pd = Leakage Power
The following factors allow direct proportional calculation of the mains current Imain for different mains
supply voltages:
100V = 2.3; 120V = 1.9; 220V = 1.05; 240V = 0.96
9
LX1600
U
mains
[V]
I
mains
[A]
P
mains
[W]
P
out
[W]
Pd
(5)
[W]
BTU/hr
(1)
idle
230
0.8
80
-
80
273
Max. Output Power @ 8Ω
(1)
230
9.6
1780
2 x 500
450
1535
Max. Output Power @ 4Ω
(1)
230
15.7
3240
2 x 800
910
3105
1/3 Max. Output Power @ 4Ω
(1)
230
9.0
1740
2 x 267
797
2718
1/8 Max. Output Power @ 4Ω
(1)
230
4.2
640
2 x 100
360
1228
1/8 Max. Output Power @ 4Ω
(2)
230
4.5
850
2 x 100
425
1450
1/8 Max. Output Power @ 4Ω
(2),(4)
253
4.8
950
2 x 121
448
1529
Normal Mode (-10dB) @ 4Ω
(1)
230
3.8
580
2 x 80
345
1177
Rated Output Power (0dB) @ 4Ω
(1)
230
14.8
2860
2 x 700
925
3156
Alert (Alarm) Mode (-3dB) @ 4Ω
(1)
230
10.4
1980
2 x 350
885
3020
Max. Output Power @ 2Ω
(1)
230
25.8
5280
2 x 1300
1750
5971
1/8 Max. Output Power @ 2Ω
(1)
230
6.7
1030
2 x 163
630
2150
1/8 Max. Output Power @ 2Ω
(2)
230
6.8
1250
2 x 163
640
2184
Summary of Contents for LX 1600
Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI SWITCHMODE PRECISION LX1600 LX2200 LX3000...
Page 11: ...BEDIENUNGSANLEITUNG LX1600 LX2200 LX3000 SWITCHMODE PRECISION...
Page 21: ...MODE D EMPLOI LX1600 LX2200 LX3000 SWITCHMODE PRECISION...
Page 32: ...BLOCK DIAGRAM 32...
Page 33: ...DIMENSIONS ABMESSUNGEN 33 Abmessungen Dimensions in mm...
Page 34: ...NOTES 34...
Page 35: ...NOTES 35...