background image

REAR PANEL

Power  amp  output  connection  for  the  two  channels  A 

(left) and B (right) is provided via professional SPEAKON 

connectors.  These  offer  an  electrical  and  mechanical 

secure  connection  which  complies  to  all  security 

regulations. It also allows the use of high quality speaker 

cables with a diameter of 4 x 2.5 mm

2

. The DYNACORD 

accessory  assortment  includes  recommended  cables 

and  connectors.  A  plastic  cover  to  prevent  inadvertent 

erroneous  connection  protects  the  BRIDGED  OUT 

connector. Remove the cover only when actually operating 

the power amplifier in Bridged-Mode.

POWER AMPLIFIER OUTPUT CONNECTORS

BRIDGED MODE

 

 

 

With the BRIDGED-MODE switch being engaged, using the channel A input  

 

 

 

for audio signal feed is 

mandatory

, since input B provides no function. While  

 

 

 

the amplifier of channel A operates as usual. Additionally, the audio signal is  

 

 

 

internally inverted and routed to the amplifier of channel B. Both amps – A 

 

 

 

and B – now work in push-pull operation to provide doubled output voltage at  

 

 

 

the BRIDGED-OUT connector.

The regular output voltage of each amplifier channel A + B is still present at the corresponding output 

connectors CHANNEL A and CHANNEL B. However, using these signals is not recommendable because 

of the aforementioned phase inversion. Operating the power amp in Bridged Mode with loads 

of 2ohms connected is not allowable.

CAUTION: Operating the power amplifier in Bridged-Mode may result in extremely high voltages 

being present at the BRIDGED OUT connector. The connected loudspeaker systems have to be 

designed for handling such high voltages. Please carefully read the power handling specifications 

as  stated  in  the  documentation  of  the  according  loudspeaker  system  and  make  sure  to  check 

whether they are in compliance with the output capacity specifications of the power amplifier.

GROUND-LIFT SWITCH

 

The ground-lift switch allows eliminating noise loops. When operating the  

 

power amplifier in a 19“ rack-shelf system or cabinet together with other  

 

equipment, setting the switch to its GROUNDED position is recommended.  

 

When operating the power amplifier together with appliances with differing  

 

ground potentials, set the switch to its UNGROUNDED position

MAINS INPUT

 

Under normal circumstances, the mains fuse only blows in case of fault. 

 

Replacing the fuse is only permissible for authorized service personnel  

 

using a new fuse of the same type with identical amperage, voltage and  

 

blow characteristics. The high-performance mains cord supplied with your  

power amplifier complies with applicable safety regulations, plus that its   diameter corresponds to the 

power amp’s power output capacity. Whenever possible make sure to use the supplied mains cord for 

connecting the power amp to the mains network. Using a different mains cord with a smaller diameter 

results in higher leakage, consequently reducing the amplifier’s maximum power output capacity.

WARNING:

The speaker output terminals are marked with a symbol “       ”,  which signifies that these 

terminals present a shock hazard to the user. 

8

CAUTION!

Pins 2+/2- of the CHANNEL A SPEAKON output, which normally are not in use, are also connected to 

output B to ensure comfortable connection of 2-way speaker cabinets (e.g in Bi-Amping Mode) when 

using 4-wire Speakon cables. To prevent short-circuit and/or to protect your speaker systems from being 

damaged when connecting the cabinets, please make sure to mind the Low- and High channels’ specific 

pin-assignments! If, for example, the subwoofer audio signal is used to feed a tweeter, it is more than 

likely that this will instantly destroy the HF-driver’s coil.

Summary of Contents for LX 1600

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI SWITCHMODE PRECISION LX1600 LX2200 LX3000...

Page 2: ...E SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER...

Page 3: ...ompletely disconnect this equipment from the AC Mains disconnect the power supply cord plug from the AC receptacle 16 The mains plug of the power supply cord shall remain readily operable CAUTION Thes...

Page 4: ...ack EMF Protection eliminates the risk of the output transistors being damaged by electrical energy back feed The power outputs are switched via relay with a time delay during soft start and an inrush...

Page 5: ...ve dust and vibrations If guaranteeing the listed requirements is not possible on a long term basis regular servicing is absolutely mandatory to prevent the power amplifier from possible failure mainl...

Page 6: ...ternal limiters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity S...

Page 7: ...always preferable A great number of today s audio appliances employ balanced outputs With balanced ca bling the shield connects all metal enclosure parts and therefore efficiently eliminates the intr...

Page 8: ...tem and make sure to check whether they are in compliance with the output capacity specifications of the power amplifier GROUND LIFT SWITCH The ground lift switch allows eliminating noise loops When o...

Page 9: ...t Power 4 2 4 253 6 1 950 2 x 166 618 2109 Normal Mode 10dB 4 1 230 4 2 580 2 x 110 360 1230 Rated Output Power 0dB 4 1 230 17 6 2860 2 x 900 1060 3617 Alert Alarm Mode 3dB 4 1 230 12 6 1980 2 x 450 1...

Page 10: ...6 2546 Normal Mode 10dB 4 1 230 6 3 896 2 x 150 595 2030 Rated Output Power 0dB 4 1 230 23 5 3900 2 x 1200 1500 5118 Alert Alarm Mode 3dB 4 1 230 16 4 2630 2 x 600 1430 4879 Max Output Power 2 1 230 4...

Page 11: ...BEDIENUNGSANLEITUNG LX1600 LX2200 LX3000 SWITCHMODE PRECISION...

Page 12: ...CKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTWICK...

Page 13: ...s kein Tropf oder Spritzwasser ins Ger teinnere eindringen kann Stellen Sie keine mit Fl ssigkeiten gef llten Objekte wie Vasen oder Trinkgef sse auf das Ger t 15 Um das Ger t komplett spannungsfrei z...

Page 14: ...ndtransistoren durch R ckeinspeisung elektrischer Energie wird durch die Back EMF Schutzschaltung verhindert Beim Softstart werden die Leistungsausg nge ber Relais verz gert zugeschaltet Zus tzlich ve...

Page 15: ...ichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Betrieb nicht berschritten werden Beim Einbau in G...

Page 16: ...et auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unp...

Page 17: ...Audioger te verf gen ber symmetrisch aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l ckenlos ein Einkop peln von e...

Page 18: ...unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprechenden Ausgangsleistung der Endstufe GROUND LIFT SCHALTER Mit dem Groundlift Schalt...

Page 19: ...x Output Power 4 2 4 253 6 1 950 2 x 166 618 2109 Normal Mode 10dB 4 1 230 4 2 580 2 x 110 360 1230 Rated Output Power 0dB 4 1 230 17 6 2860 2 x 900 1060 3617 Alert Alarm Mode 3dB 4 1 230 12 6 1980 2...

Page 20: ...ormal Mode 10dB 4 1 230 6 3 896 2 x 150 595 2030 Rated Output Power 0dB 4 1 230 23 5 3900 2 x 1200 1500 5118 Alert Alarm Mode 3dB 4 1 230 16 4 2630 2 x 600 1430 4879 Max Output Power 2 1 230 40 7 7200...

Page 21: ...MODE D EMPLOI LX1600 LX2200 LX3000 SWITCHMODE PRECISION...

Page 22: ...DESCRIPTION 24 D BALLAGE ET GARANTIE 25 REMARQUES SUR L INSTALLATION 25 FACE AVANT 26 PANNEAU ARRI RE 27 INPUT A INPUT B 27 PARALLEL 27 SORTIE DE AMPLI DE PUISSANCE 28 GROUND LIFT 28 ENTR E SECTEUR 28...

Page 23: ...ne soit pos dessus 15 Pour d brancher compl tement l appareil du secteur il faut d brancher le cordon secteur de la prise lectrique 16 La prise du cordon secteur doit toujours tre accessible CAUTION...

Page 24: ...s Audio Pro Une protection contre la force lectro motrice Back EMF limine le risque d endommager les transistors de sortie par un retour de l nergie lectrique Les sorties de puissance sont commut es v...

Page 25: ...es 40 C en fonctionnement n oubliez pas que la temp rature ambiante maximale doit aussi pouvoir tre support e par tous les autres appareils install s dans cette armoire reportez vous galement au FONCT...

Page 26: ...e plus le t moin 0dB est aussi tr s pratique pour r gler les limiteurs externes Ce t moin s allume aussi d s que le limiteur de signal audio dynamique int gr est activ et que l amplificateur de puissa...

Page 27: ...and nombre d appareils audio est aujourd hui quip de sorties sym tris es Avec un c blage sym tris le blindage relie toutes les parties m talliques du ch ssis et limine donc plus efficacement la pr sen...

Page 28: ...n es dans la documentation qui accompagne vos haut parleurs correspondent celles de l amplificateur de puissance COMMUTATEUR GROUND LIFT Le commutateur de masse Ground Lift permet d liminer les bruits...

Page 29: ...576 1965 1 8 Max Output Power 4 2 4 253 6 1 950 2 x 166 618 2109 Normal Mode 10dB 4 1 230 4 2 580 2 x 110 360 1230 Rated Output Power 0dB 4 1 230 17 6 2860 2 x 900 1060 3617 Alert Alarm Mode 3dB 4 1...

Page 30: ...ormal Mode 10dB 4 1 230 6 3 896 2 x 150 595 2030 Rated Output Power 0dB 4 1 230 23 5 3900 2 x 1200 1500 5118 Alert Alarm Mode 3dB 4 1 230 16 4 2630 2 x 600 1430 4879 Max Output Power 2 1 230 40 7 7200...

Page 31: ...wer 4 7 dBu 1 33 V rms 5 8 dBu 1 55 V rms 7 0 dBu 1 74 V rms THD at rated output power MBW 80kHz 1kHz 0 05 IMD SMPTE 60Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 05 Maximum Input Level 22dBu 9 76 Vrms Crossta...

Page 32: ...BLOCK DIAGRAM 32...

Page 33: ...DIMENSIONS ABMESSUNGEN 33 Abmessungen Dimensions in mm...

Page 34: ...NOTES 34...

Page 35: ...NOTES 35...

Page 36: ...ille MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior noti...

Reviews: