FRONT PANEL
This indicator lights when the power amplifier has been switched on. Causes for
the POWER-indicator not lighting are: the appliance is not connected to the mains
network or a defective primary fuse.
The PROTECT LED lights indicating that one of the internal protection circuits
against thermal overload, short-circuit, Back-EMF, HF-occurrence at the output,
etc., has been activated. The output relays interrupt the connected loads from
the power amps while input signals are interrupted as well, preventing the connected
loudspeaker systems and the power amplifier itself from being damaged.
Whatever caused the fault – e.g. a short-circuited speaker cable – needs to be
remedied. In case of thermal overload you have to wait until the power amplifier
automatically regains normal operation.
The SIGNAL LED lights as soon as an audio signal of approximately 30dB below full
modulation is present at the output. The LED is dimmed when speaker cables are
short-circuited or a protection circuit has been activated.
The 0dB LED lights whenever the power amplifier is driven at its limits. Higher input
voltage does not result in higher peak output voltage. In addition, the 0dB indicator
comes in handy when adjusting external limiters.
This indicator lights as soon as the integrated dynamic audio signal limiter is
activated and the power amplifier is driven at the clipping limit or generally
at its maximum capacity. Short-term blinking is not a problem, because the internal
limiter trims input levels of up to +21dBu down to an S/N-ratio of approximately 1%.
If, on the other hand, this LED lights constantly, reducing the volume is
recommended to prevent the loudspeaker systems connected from being damaged
by probable overload.
Detent potentiometers scaled in dB (steps of 1dB) for
adjusting the power amp’s overall amplification. To prevent
distortion in mixing consoles connected to the amp, setting
these controls to a value between 0dB and -6dB is generally
recommended. The dB-scale provides direct indication of the
control attenuation applied to the fixed internal amplification.
Use the
POWER switch
located on the front panel to power-on the appliance. The soft-start function
protects against current inrush peaks on the mains, which in addition prevents the mains line protection
switch from activating during power-on. The loudspeaker outputs are activated via relay switching with
a delay of approximately 3 seconds to efficiently attenuate eventual power-on noise. The PROTECT
LED lights during the delay time and the fans run at maximum speed. This is normal, confirming the
immaculate operation of the protection circuitry.
6
Summary of Contents for LX 1600
Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI SWITCHMODE PRECISION LX1600 LX2200 LX3000...
Page 11: ...BEDIENUNGSANLEITUNG LX1600 LX2200 LX3000 SWITCHMODE PRECISION...
Page 21: ...MODE D EMPLOI LX1600 LX2200 LX3000 SWITCHMODE PRECISION...
Page 32: ...BLOCK DIAGRAM 32...
Page 33: ...DIMENSIONS ABMESSUNGEN 33 Abmessungen Dimensions in mm...
Page 34: ...NOTES 34...
Page 35: ...NOTES 35...