The lightning flash with arrowhead symbol, within an 

equilateral triangle is intended to alert the user to the 

presence of uninsulated „dangerous voltage“ within 

the  product’s  enclosure  that  may  be  of  sufficient 

magnitude  to  constitute  a  risk  of  electric  shock  to 

persons.

The exclamation point within an equilateral triangle 

is intended to alert the user to the presence of 

important operating and maintance (servicing) 

instructions in the literature accompanying the 

appliance.

1.  

Read these instructions.

2. 

Keep these instructions. 

3.  

Heed all warnings.

4. 

Follow all instructions.

5.  

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7.  

Do not block any ventilation openings. Install in accordance with the manufactures instructions.

8. 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 

 

(including amplifiers) that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades    

 

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide    

 

blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an  

 

electrican for replacement of the absolete outlet.

10. 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,  

 

 

and the point where they exit from the apparatus. 

11. 

Only use attachments/accessories specified by the manufacturer.

12. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

13.  

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged  

 

in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the  

 

apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14.  

Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases,  

 

are placed on the equipment.

15. 

To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC  

 

receptacle.

16.  

The mains plug of the power supply cord shall remain readily operable.

CAUTION:

  

These servicing instructions are for use by qualified personnel only. To reduce the risk of    

 

 

electric shock, do not perform any servicing other than that contained in the Operating 

 

 

Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1. 

Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when 

 

servicing the appliance.

2. 

Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be  

 

operated and is connected to the mains.

3. 

Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4. 

The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure),  

 

respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance  

 

between parts carrying mains voltage and any switches or breakers that are not connected  to the mains (secondary  

 

parts) has to be 6 mm and needs to be minded at all times.

5. 

Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only  

 

permissible when using original parts.

6. 

Altering the circuitry without prior consent or advice is not legitimate.

7. 

Any work security regulations that are applicable at the location where the appliance is being serviced have to be  

 

strictly obeyed. This applies also to any regulations about the work place itself.

8. 

All instructions concerning the handling of MOS - circuits have to be observed. 

SAFETY COMPONENT ( MUST BE REPLACED BY ORIGINAL PART )

NOTE:

IMPORTANT SERVICE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Management of WEEE (waste electrical and electronic equipment) (applicable in Member States of the European 

Union and other European countries with individual national policies on the management of WEEE) The symbol on 

the product or on its packaging indicates that this product may not be treated as regular household waste, but has 

to be disposed through returning it at a Telex dealer. 

Summary of Contents for LX 1600

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI SWITCHMODE PRECISION LX1600 LX2200 LX3000...

Page 2: ...E SERVICEHINWEISE 13 BESCHREIBUNG 14 AUSPACKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER...

Page 3: ...ompletely disconnect this equipment from the AC Mains disconnect the power supply cord plug from the AC receptacle 16 The mains plug of the power supply cord shall remain readily operable CAUTION Thes...

Page 4: ...ack EMF Protection eliminates the risk of the output transistors being damaged by electrical energy back feed The power outputs are switched via relay with a time delay during soft start and an inrush...

Page 5: ...ve dust and vibrations If guaranteeing the listed requirements is not possible on a long term basis regular servicing is absolutely mandatory to prevent the power amplifier from possible failure mainl...

Page 6: ...ternal limiters This indicator lights as soon as the integrated dynamic audio signal limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity S...

Page 7: ...always preferable A great number of today s audio appliances employ balanced outputs With balanced ca bling the shield connects all metal enclosure parts and therefore efficiently eliminates the intr...

Page 8: ...tem and make sure to check whether they are in compliance with the output capacity specifications of the power amplifier GROUND LIFT SWITCH The ground lift switch allows eliminating noise loops When o...

Page 9: ...t Power 4 2 4 253 6 1 950 2 x 166 618 2109 Normal Mode 10dB 4 1 230 4 2 580 2 x 110 360 1230 Rated Output Power 0dB 4 1 230 17 6 2860 2 x 900 1060 3617 Alert Alarm Mode 3dB 4 1 230 12 6 1980 2 x 450 1...

Page 10: ...6 2546 Normal Mode 10dB 4 1 230 6 3 896 2 x 150 595 2030 Rated Output Power 0dB 4 1 230 23 5 3900 2 x 1200 1500 5118 Alert Alarm Mode 3dB 4 1 230 16 4 2630 2 x 600 1430 4879 Max Output Power 2 1 230 4...

Page 11: ...BEDIENUNGSANLEITUNG LX1600 LX2200 LX3000 SWITCHMODE PRECISION...

Page 12: ...CKEN GARANTIE 15 INSTALLATIONSHINWEISE 15 FRONTSEITE 16 R CKSEITE 17 INPUT A INPUT B 17 PARALLEL 17 ENDSTUFENAUSG NGE 18 BRIDGED MODE 18 GROUND LIFT SCHALTER 18 NETZEINGANG 18 NETZBETRIEB W RMEENTWICK...

Page 13: ...s kein Tropf oder Spritzwasser ins Ger teinnere eindringen kann Stellen Sie keine mit Fl ssigkeiten gef llten Objekte wie Vasen oder Trinkgef sse auf das Ger t 15 Um das Ger t komplett spannungsfrei z...

Page 14: ...ndtransistoren durch R ckeinspeisung elektrischer Energie wird durch die Back EMF Schutzschaltung verhindert Beim Softstart werden die Leistungsausg nge ber Relais verz gert zugeschaltet Zus tzlich ve...

Page 15: ...ichen Ger te beachtet werden siehe auch Kapitel NETZBETRIEB UND W RMEENTWICKLUNG Achtung Die max Umgebungstemperatur von 40 C soll f r st rungsfreien Betrieb nicht berschritten werden Beim Einbau in G...

Page 16: ...et auf sobald einer der eingebauten dynamische Audio Limiter anspricht und die Endstufe ber der Aussteuerungsgrenze oder generell im Grenz bereich betrieben wird Kurzzeitiges Aufleuchten ist dabei unp...

Page 17: ...Audioger te verf gen ber symmetrisch aufgebaute Ausg nge Der Schirm im Kabel verbindet bei symmetrischer Signalf hrung alle metallischen Geh use und verhindert dadurch l ckenlos ein Einkop peln von e...

Page 18: ...unbedingt die Leistungsangaben im Datenblatt des jeweiligen Lautsprechers und vergleichen Sie diese mit der entsprechenden Ausgangsleistung der Endstufe GROUND LIFT SCHALTER Mit dem Groundlift Schalt...

Page 19: ...x Output Power 4 2 4 253 6 1 950 2 x 166 618 2109 Normal Mode 10dB 4 1 230 4 2 580 2 x 110 360 1230 Rated Output Power 0dB 4 1 230 17 6 2860 2 x 900 1060 3617 Alert Alarm Mode 3dB 4 1 230 12 6 1980 2...

Page 20: ...ormal Mode 10dB 4 1 230 6 3 896 2 x 150 595 2030 Rated Output Power 0dB 4 1 230 23 5 3900 2 x 1200 1500 5118 Alert Alarm Mode 3dB 4 1 230 16 4 2630 2 x 600 1430 4879 Max Output Power 2 1 230 40 7 7200...

Page 21: ...MODE D EMPLOI LX1600 LX2200 LX3000 SWITCHMODE PRECISION...

Page 22: ...DESCRIPTION 24 D BALLAGE ET GARANTIE 25 REMARQUES SUR L INSTALLATION 25 FACE AVANT 26 PANNEAU ARRI RE 27 INPUT A INPUT B 27 PARALLEL 27 SORTIE DE AMPLI DE PUISSANCE 28 GROUND LIFT 28 ENTR E SECTEUR 28...

Page 23: ...ne soit pos dessus 15 Pour d brancher compl tement l appareil du secteur il faut d brancher le cordon secteur de la prise lectrique 16 La prise du cordon secteur doit toujours tre accessible CAUTION...

Page 24: ...s Audio Pro Une protection contre la force lectro motrice Back EMF limine le risque d endommager les transistors de sortie par un retour de l nergie lectrique Les sorties de puissance sont commut es v...

Page 25: ...es 40 C en fonctionnement n oubliez pas que la temp rature ambiante maximale doit aussi pouvoir tre support e par tous les autres appareils install s dans cette armoire reportez vous galement au FONCT...

Page 26: ...e plus le t moin 0dB est aussi tr s pratique pour r gler les limiteurs externes Ce t moin s allume aussi d s que le limiteur de signal audio dynamique int gr est activ et que l amplificateur de puissa...

Page 27: ...and nombre d appareils audio est aujourd hui quip de sorties sym tris es Avec un c blage sym tris le blindage relie toutes les parties m talliques du ch ssis et limine donc plus efficacement la pr sen...

Page 28: ...n es dans la documentation qui accompagne vos haut parleurs correspondent celles de l amplificateur de puissance COMMUTATEUR GROUND LIFT Le commutateur de masse Ground Lift permet d liminer les bruits...

Page 29: ...576 1965 1 8 Max Output Power 4 2 4 253 6 1 950 2 x 166 618 2109 Normal Mode 10dB 4 1 230 4 2 580 2 x 110 360 1230 Rated Output Power 0dB 4 1 230 17 6 2860 2 x 900 1060 3617 Alert Alarm Mode 3dB 4 1...

Page 30: ...ormal Mode 10dB 4 1 230 6 3 896 2 x 150 595 2030 Rated Output Power 0dB 4 1 230 23 5 3900 2 x 1200 1500 5118 Alert Alarm Mode 3dB 4 1 230 16 4 2630 2 x 600 1430 4879 Max Output Power 2 1 230 40 7 7200...

Page 31: ...wer 4 7 dBu 1 33 V rms 5 8 dBu 1 55 V rms 7 0 dBu 1 74 V rms THD at rated output power MBW 80kHz 1kHz 0 05 IMD SMPTE 60Hz 7kHz 0 02 DIM30 3 15kHz 15kHz 0 05 Maximum Input Level 22dBu 9 76 Vrms Crossta...

Page 32: ...BLOCK DIAGRAM 32...

Page 33: ...DIMENSIONS ABMESSUNGEN 33 Abmessungen Dimensions in mm...

Page 34: ...NOTES 34...

Page 35: ...NOTES 35...

Page 36: ...ille MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior noti...

Reviews: