User’s Manual
43
activating this function, alarm connection setups must be completed in advance.
•
DETECT SWITCH
The item is used to enable or disable the ALARM DETECT function.
•
DETECT MODE
Four alarm detect modes are provided for different application.
INT FOCUS (Internal Focus)
The alarm will be triggered if the internal focus changes; if the focus returns
to the original position, the alarm will stop.
FIX FOCUS
If focus movement is detected, the alarm will be triggered, and the alarm
stops when focus returns to the original position. If the detected focus
movement keeps changing for more than four seconds, the new focus
position will be memorized as the reference, and the alarm will stop.
NOTE:
The INT FOCUS and FIX FOCUS detect modes will be
activated only with the Auto Focus mode.
INT AE (Internal AE)
When Auto Exposure (AE) movement is detected, the alarm will be
triggered; if the Exposure Level returns to the original level, the alarm will
stop.
FIX AE
The alarm will be triggered if the Exposure value changes; if the adjusted
AE value retains for four seconds, the value will be saved as the reference,
and the alarm will stop.
•
EXIT
Exit the
ALARM DETECT
menu.
3.3.20 WDR FUNCTION (K Model Only)
The Wide Dynamic Range (WDR) function is especially effective in solving
indoor and outdoor contrast issues to enhance better image quality and video
display. It enables the dome to catch detailed data from the dark part (Indoor)
ALARM DETECT
DETECT SWITCH
OFF
DETECT MODE
INT FOCUS
EXIT
YES