User’s Manual
11
RS-485 is the interface that communicates the dome camera and its control
device; for this reason, the RS-485 setup of the dome and the control device
must be the same. The RS-485 default setting is half-duplex (see the diagram
follows). Please do not change the default setting without qualified specialist or
supplier’s notice. As for the SW 3 and SW 4, they are used for termination and
Line Lock adjustment respectively. The SW 5 is mainly used when users want to
restore the camera to the factory default status; moreover, once firmware
upgrade is carried out, users also need to reset the SW 5 afterward.
RS-485 Setting
Half-duplex
Full-duplex
2.4
Dome ID Setting
Use the switch to change your speed dome ID by turning the arrow to the
desired number respectively. For instance, if the dome ID is 123, the ID switch
should be set as below.
NOTE:
No two domes should be given the same ID, or communication
conflict may occur.
Centesimal Digit Decimal Digit Single Digit
NOTE:
The number “0” should locate upwards as shown in the diagram
above for correct switch definition.