8
Using T
his Pr
oduct
Ins
talling T
his Pr
oduct
A ground fault circuit breaker must be installed in the circuit that supplies power to this product.
Ground Fault Circuit Breaker
Power Supply
Grounding
Installation Location
Water Supply
Unit : mm (inch)
Remote control
1.18" (30 mm) or more
1.18" (30 mm) or more
8.15"
(207 mm)
8.62"
(219 mm)
47.24" (1200 mm) or more
15.75" (400 mm) or more
16.77"
(426 mm )
Elongated type: 21.5" (547 mm)
Round type: 20.8" (527 mm)
Unit : mm (inch)
Remote control
1.18" (30 mm) or more
1.18" (30 mm) or more
8.15"
(207 mm)
8.62"
(219 mm)
47.24" (1200 mm) or more
15.75" (400 mm) or more
16.77"
(426 mm )
Elongated type: 21.5" (547 mm)
Round type: 20.8" (527 mm)
Checking the Bathroom
The dimensions required for mounting this product
on a toilet are shown in the figure below. Check
to make sure there is sufficient space inside the
bathroom and that there are no obstructions.
DANGER:Improper use of the grounding plug may cause an electric shock.
Use only the tap water line to supply water to this product. The use of any other type of
water i.e. ground water may cause improper operation of this product.
The tap water pressure must be 8.5 to 106.7 psi (0.06 to 0.74 MPa, 0.6 to 7.5 kgf/cm
2
).
This product is for use on a nominal 120 V circuit. Use a 120 V, 60 Hz power supply. The
maximum power consumption is 301 W. Electrical wiring must be installed that meets these
specifications. The plug outlet shall be placed in an accessible location after installation.
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk
of electric shock by providing an escape wire for the electric current. The power cord has a grounding
wire and a three-prong grounding plug (shown below). Do not use an adapter with the product's power
plug, or use any other unauthorized method to connect the plug to an improperly configured outlet.
The outlet to which the product is connected must be 120 V, 60 Hz, with a minimum electrical rating of 3
A. The outlet must be properly installed and grounded, and it must be a three-slot outlet (shown below).
If it is necessary to use an extension cord, use only a three wire extension cord that has a
three-prong grounding plug. The extension cord must be rated for at least 120 V, 60 Hz, 3 A.
In order to prevent damaging the electronic components, install this product at a location
that minimizes the possibility of it getting wet. In extremely humid conditions, provide
adequate ventilation by operating an exhaust fan or opening a window or door.