Installing the optional Feedline Current Choke
Using the optional
DXE-BMB-1P
, attach the long aluminum strip to the
bottom of the optional
DXE-FCC050-H05-A
Feedline Current Choke.
Place the Feedline Current Choke on the Center Post using the two stainless
steel band clamps (included with the
DXE-BMB-1P
). One clamp is located
below the 20 meter feed point clamp and the lower band clamp is located
above the 17 meter element clamp as shown in
Figure 10
. Connect the
coaxial pigtail to the top of the Feedline Current Choke. If the optional
Feedline Current Choke is not installed, use the supplied UHF to UHF
adapter to connect your RG-213 (or equivalent) coaxial cable to the feedline
pigtail.
Figure 10