Quick Start (cont’d)
Shipping Cleats.
(Refer to Page 6)
Lubrication.
Rotation.
(Refer to Page 11)
(Refer to Page 13)
Cover Plate
Correct
Oil Level
Before starting the Unit for
the first time, ensure the oil
level in the Reservoir is as
shown below at the Oil
Sight Glass.
Check the oil after the Unit
has been at rest for a
minimum of 10 minutes.
The Unit is not equipped with an ‘Anti
Rotation’ Switch. Operating the Unit in the
reverse direction will cause irreparable
damage.
Remove the Cover Plate from the Coupling
area and pay close attention to the arrow
indicating correct rotation. Turn Unit on and
immediately turn off using the Emergency
Stop Button.
If the rotation is not correct, simply change
two of the motor leads at the Inverter.
Reservoir
Couplings
The ‘K Series’ Screw Units are shipped
with (3) Shipping Cleats under the Feet
of the Oil Receiver, (1) under Air End
Bracket, and (1) under the Motor.
These Cleats are installed simply to
stop any lateral movement of the
components during transportation.
The Cleats must be removed before
starting the Unit.
Cleat
(1of 3) Cleats at
Oil Receiver
Locate the Orange
Cleats located under
each Foot of the Oil
Receive.
Locate the Orange Cleat
located under the Air
End Bracket.
Remove the Bolts and
Washers from each
Cleat, and slide the
Cleats out.
Motor Cleat from Front of Unit.
Motor Cleat from Rear of Unit.
Cleat
Remove the Fasteners
from the Cleat.
Slide the Cleat from
under the Motor.
Cleat at Air End