Error
Possible cause
Remedy
Knocking or loud noises on
the compressor
Compressor unit defective
❯
Disconnect all power from the
device and inform a service
technician.
Reduced delivery. Compres-
sor needs longer to charge
the pressure tank, see charg-
ing times in
Air intake filter dirty
❯
Replace the air intake filter at
least 1x per year. The air
intake filter must never be
cleaned.
Defective membrane drying unit
❯
Replace the membrane drying
unit.
❯
Inform a Service Technician.
Water dripping from air con-
sumers
Maintenance work not carried
out regularly (without membrane
drying unit)
❯
Regularly drain the condensa-
tion water from the pressure
tank, see "10.4 Draining the
condensation water"
Defective membrane drying unit
❯
Inform a service technician.
Troubleshooting
40
5152100003L02 1910V001
EN