9
Installation
9.1
Remove the transport locks
For safe transport, the unit is secured with foam
padding blocks and a transport strap.
❯
Cut and remove the transport strap.
❯
Remove the foam padding blocks.
9.2
Establishing the compressed
air connection
The supplied flexible pressure hose
between the pipe system and the com-
pressor prevents vibrations from being
transmitted and thus reduces noise. This
ensures safe and reliable operation.
❯
Connect the pre-assembled connecting sleeve
of the pressure hose to the quick release cou-
pling.
❯
Measure the required length of the pressure
hose and shorten if necessary.
❯
Press a fitting hose connector (not included in
the scope of delivery) onto the pressure hose
(internal diameter 10 mm) and secure it with a
hose clip.
❯
Connect the connecting sleeve of the pressure
hose to the compressed air tube.
Fig. 1: Duo with condensate separator
9.3
Pressure reducer
❯
Insert the pressure reducer into the quick
release coupling.
❯
Insert the pressure hose into the quick release
coupling on the pressure reducer.
9.4
Place a collector tray under-
neath
During operation, condensation water on the unit
is continuously separated and automatically
drained. In order to prevent water damage due to
drained condensation, it is collected in the collec-
tor tray.
As an option, the condensation can also
be drained through a hose into the waste
water system. Always comply with appli-
cable national regulations for waste water
systems.
Assembly
26
5152100003L02 1910V001
EN