Transport
WARNING
Risk of explosion of the pressure tank
and pressure hoses
❯
The pressure tank and the pressure
hoses must be vented before they are
stored or transported.
❯
Protect the unit against moisture, dirt and
extreme temperatures during transport ("4
Technical data").
❯
Always make sure that the condensate collec-
tor chamber is empty before transporting the
unit ("15 Taking out of use").
❯
Always transport the unit in an upright position.
❯
Only transport the unit using the transport han-
dles provided.
❯
Check the unit for transport damage.
8
Quattro Tandem assembly
and installation
For weight reasons the unit is not supplied fully
assembled. Instead, the compressor units are
installed at the site of use.
❯
Set up the tank at the planned installation site.
❯
Screw in the vibration dampers into the motor
mounting.
❯
Place the compressors on the vibration damp-
ers.
❯
Attach the compressor units with the lock
washers and nuts.
❯
Insert the compressed air connections from the
compressor unit into the cooler.
❯
Plug in the electrical connections of the com-
pressor units at the control box. Connect the
left-hand unit to the left-hand plug connector
and the right-hand unit to the right-hand plug
connector.
1
2
1
1
Compressed air connection
2
Electrical connection
Assembly