Pre-setting in Manual Mode
•
modify the base parameters:
• stitch length 5.0 mm
• needle thread tension 25%
• sewing foot pressure 5
• sewing foot stroke 1,5 mm
•
modify the other parameters
P…
• Thread Trim active On
• Start bartack active (On)
•
Number of backward stitches (3 points)
•
Number of forward stitches (3 points)
•
St.Len.Def
– Default stitch length active (On)
• End bartack active (On)
•
Number of backward stitches (4 points)
•
Number of forward stitches (4 points)
•
St.Len.Def
– Default stitch length inactive (Off)
– backward stitch length (2.5 mm)
– forward stitch lengths (2.5 mm)
• Gap (edge guide): 10 mm
During sewing process
•
start sewing
(automatic start bartack)
•
activate/deactivate the auxiliary values:
• activate 2
nd
stitch length
• activate 2
nd
foot stroke
• activate 2
nd
thread tension
• deactivate the secondary values
•
interrupt the sewing process (pedal)
• lift your foot from pedal
• continue sewing process / resume
•
stop sewing, end of seam (pedal -2)
(automatic end bartack)
Exercise: Sewing in Manual Mode, other parameters
27
Summary of Contents for M-TYPE PREMIUM
Page 1: ...M TYPE PREMIUM USER TRAINING...
Page 9: ...Video 9 Stitch Length Thread Tension Foot Pressure Footstroke...
Page 11: ...M TYPE PREMIUM 11...
Page 14: ...Function Buttons Favorite Button Push Buttons soft keys 14 press and turn vertically...
Page 15: ...15 Function Buttons Notes...
Page 21: ...Manual Mode Other Parameters 21...
Page 22: ...Manual Mode Other Parameters Notes 22...
Page 23: ...23 Manual Mode Other Parameters Notes...
Page 24: ...24 Manual Mode Other Parameters Notes...
Page 30: ...Parameter Fabric Thickness Notes 30...
Page 34: ...34 Functions Softkey Menu 2nd page...
Page 44: ...QUESTIONS 44...
Page 45: ...THANK YOU FOR YOUR ATTENTION 45...
Page 49: ...49 Program Parameters Notes...
Page 50: ...50 Program Parameters Notes...
Page 51: ...51 Program Parameters Notes...
Page 54: ...Programming Mode Notes...
Page 66: ...QUESTIONS 66...