Troubleshooting
Instructions for use DAC eco M-Type - 01.0 - 10/2015
32
14
Error
Incorrect sewing
motor direction of
rotation
• Exchange encoder
• Check motor plug
assignment and
change, if neces-
sary
• Check wiring on
machine distributor
and change if nec-
essary
• Test motor phases
and check for cor-
rect value
15
Error
Sewing motor over-
current:
Internal current rise >
25 A
• Replace controller
16
Error
Maximum speed
exceeded
• Replace encoder
17
Error
AC-RDY Timeout:
intermediate circuit
voltage did not reach
the defined threshold
in the specified time
• Check the line volt-
age
• If the line voltage is
OK, replace the
controller
18
Information
No valid data on
external
EEprom
• Check machine ID
connection
• Switch off the con-
troller, wait until the
LEDs are off and
then switch on
again
• Update the software
19
Information
No valid data on
external
EEprom
• Check machine ID
connection
• Switch off the con-
troller, wait until the
LEDs are off and
then switch on
again
• Update the software
Code
Type
Description
Remedial action
Summary of Contents for DAC eco M-Type
Page 1: ...DAC eco M Type Instructions for use...
Page 4: ...Table of Contents Instructions for use DAC eco M Type 01 0 10 2015 2...
Page 18: ...Components and functions Instructions for use DAC eco M Type 01 0 10 2015 16...
Page 30: ...Electrical connection Instructions for use DAC eco M Type 01 0 10 2015 28...
Page 36: ...Glossary Instructions for use DAC eco M Type 01 0 10 2015 34...
Page 38: ...Appendix Instructions for use DAC eco M Type 01 0 10 2015 36 Fig 6 IT net wiring diagram...
Page 39: ......