Troubleshooting
Instructions for use DAC eco M-Type - 01.0 - 10/2015
31
8
Error
Sewing motor not
connected
• Check the connec-
tion
• Test sewing motor
phases (R = 2.8
Ω
,
high impedance to
PE)
• Replace sewing
motor
• Replace controller
9
Error
Sewing motor insula-
tion error
• Check motor phase
and PE for low-
impedance connec-
tion
• Replace sewing
motor
10
Error
High-voltage error:
Live voltage for
extended period >
290 V
• Check line voltage,
if line voltage
exceeds continu-
ously:
• Stabilize or use gen-
erator
11
Error
EEprom communica-
tion error
• Check machine ID
connection
• Switch off the con-
troller, wait until the
LEDs are off and
then switch on
again
12
Information
No valid data on
external
EEprom
• Check machine ID
connection
• Switch off the con-
troller, wait until the
LEDs are off and
then switch on
again
• Update the software
13
Error
Low voltage warning
(2nd threshold):
Live voltage < 150 V
AC
• Check the line volt-
age
• Stabilize the line
voltage
• Use generator
Code
Type
Description
Remedial action
Summary of Contents for DAC eco M-Type
Page 1: ...DAC eco M Type Instructions for use...
Page 4: ...Table of Contents Instructions for use DAC eco M Type 01 0 10 2015 2...
Page 18: ...Components and functions Instructions for use DAC eco M Type 01 0 10 2015 16...
Page 30: ...Electrical connection Instructions for use DAC eco M Type 01 0 10 2015 28...
Page 36: ...Glossary Instructions for use DAC eco M Type 01 0 10 2015 34...
Page 38: ...Appendix Instructions for use DAC eco M Type 01 0 10 2015 36 Fig 6 IT net wiring diagram...
Page 39: ......