Setup
Operating Instructions 669 - 00.0 - 08/2019
95
6.13.4 Connecting the sewing light transformator
A neutral conductor must be used if you are connecting the trans-
former to a three-phase 3 x 380V - 415 V power supply.
Fig. 62: Connecting the sewing light transformator
To connect the sewing light transformator:
1. Switch off the machine.
2. Unplug the main plug.
3. Route the mains cable (1) of the sewing-light transformer (2)
to the main switch.
4. Make the connection on the mains side of the main switc (see
connection diagram
9800 169002 B).
5. Put the sticker with the safety notice on the front of the main
switch.
(1) - Mains cable
(2) - Sewing light transformator
①
②