Designing Your Installation
975-0347-01-01
3–5
Choosing an Appropriate Location
The Duracell must only be installed in a location that is:
:
WARNING: Explosion or fire hazard
The Duracell contains components that tend to produce arcs or sparks. To
prevent fire or explosion, do not install the inverter in compartments
containing batteries or flammable materials, or in locations that require
ignition-protected equipment.
WARNING: Fire hazard
To reduce the risk of fire, do not cover or obstruct the ventilation
openings. Do not install the Duracell in a zero-clearance compartment.
Overheating may result.
Dry
Do not allow water or other liquids to drop or splash on it.
Cool
Ambient air temperature should be between 32 ºF and
105 ºF (0 ºC and 40 ºC)—the cooler the better within this
range.
Ventilated
Allow at least 3 inches (7.5 cm) of clearance around the
inverter for air flow. Ensure that the ventilation openings on
the DC end and on the AC end of the unit are not obstructed.
Safe
Do not install the inverter in the same compartment as
batteries or in any compartment capable of storing
flammable liquids like gasoline.
Close to
battery
Do not use excessive DC cable lengths: they increase wire
resistance and reduce input power. Longer AC wires are
preferable to longer DC wires: wire resistance (and
therefore voltage drop) is less and the cost is lower.
Protected from
battery gases
Do not mount the inverter where it will be exposed to gases
produced by batteries. Battery gases are corrosive, and
prolonged exposure to battery gases will damage the
inverter.
Duracell1000.book Page 5 Friday, September 7, 2007 1:47 PM
Summary of Contents for inverter 1000
Page 1: ...Owner s Guide 975 0347 01 01 REV B Printed in China t 1 408 987 6359 www xantrex com support ...
Page 2: ...Owner s Guide ...
Page 13: ...xii ...
Page 19: ...2 4 ...
Page 35: ...3 16 ...
Page 47: ...A 2 975 0347 01 01 Mounting Templates ...
Page 59: ...C 4 ...