Operating Limits
975-0347-01-01
4–3
Operating Limits
Power Output
The Duracell can deliver up to 1000 watts continuous.
The wattage rating applies to resistive loads such as incandescent lights.
Input Voltage
The allowable Duracell input voltage ranges are shown in the following
table:
Operating
Condition
Voltage Range
Comment
Normal
10.5 V–15.0 V
Optimum
Performance
12.0 V–13.0 V
Low Voltage Alarm
11.0 V or less
The audible low battery alarm
sounds.
Low Voltage
Shutdown
less than 10.5 V The inverter shuts down to protect the
battery from being over-discharged.
High Voltage
Shutdown
15.0 V or more
The inverter shuts down to protect
itself from excessive input voltage.
Note:
Although the Duracell
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.
Duracell1000.book Page 3 Friday, September 7, 2007 1:47 PM
Summary of Contents for inverter 1000
Page 1: ...Owner s Guide 975 0347 01 01 REV B Printed in China t 1 408 987 6359 www xantrex com support ...
Page 2: ...Owner s Guide ...
Page 13: ...xii ...
Page 19: ...2 4 ...
Page 35: ...3 16 ...
Page 47: ...A 2 975 0347 01 01 Mounting Templates ...
Page 59: ...C 4 ...