Examples for the possible use of telemetry controls
If the model speed is less than X m/s, flaps will be raised
•
automatically.
If the current is larger than X amperes, the motor run timer starts.
•
If the motor temperature is higher than 80 °C, the maximum
•
throttle will be limited by the mix.
•
If the on-state of the limit switch is detected, the sequencer
automatically starts. (ex. after opening the landing gear doors, the
main gear will be deployed).
Setting the parameters of telemetry controls
Description
– Sensor name that will be displayed in the list for easier
orientation.
Active
– Tick to enable the telemetry control function.
Sensor
– Here you can select a specific telemetry parameter.
Type of control
– Select Switch or Proportional control according to
the required functionality.
Condition (X<, X>, X=)
–
Select the condition under which you want
the control to be active (ie switched on). In the same line, fill in the
numerical value of the decision levels and the hysteresis value
(prefixed with ±). Available in Switch mode.
•
Example 1:
The entry “X < 20.0m/s ± 2.0m/s” means that
telemetry control switches precisely when the telemetry parameter
value is less than 18 m/s (due to hysteresis of 2 m/s). The control then
symmetrically switches off when the speed exceeds 22 m/s.
•
Example 2:
The entry “X > 0 ± 0” indicates a switch that is
activated whenever the telemetry value is positive.
Duration
–
Minimum time of being switched on. If an event takes a
very short time, it is possible to extend the time of the telemetry
control being switched on for the time specified by this parameter.
Available in the Switch mode.
Range
–
Set the operating range of the sensor (minimum value,
center value, and maximum value). This level will then be
transformed into a proportional range of the control (-100%, 0%,
100%). Available in Proportional Control Mode.
Filtering
–
Determines the level of received telemetry values
smoothing (filtering). The higher the level of filtration, the smoother
the course, but the response will be slower. Available in Proportional
Control Mode.
Default
– The default control value, if the sensor is not present in the
model or the model is not turned on.
Switch
–
This parameter can specify any switch, which will activate or
deactivate the operation of the telemetry control.
9.3.9
Sound of Proportional Controls
In this menu, you can set a sound notification for up to four
independent controls. You can choose a basic beep in the middle
4.
4.
99
Summary of Contents for Jeti DS-12
Page 2: ...computer radio control system EN...
Page 8: ...computer radio control system EN 8...
Page 51: ...computer radio control system EN 3 3 51...
Page 147: ...computer radio control system EN...
Page 148: ...computer radio control system EN...
Page 149: ...computer radio control system EN...
Page 150: ...computer radio control system EN...
Page 151: ...computer radio control system EN JETI model s r o Lomen 1530 742 58 P bor www jetimodel com...