computer radio control system
EN
1.
Creating an Alarm
Use the
„F2(Add)“
button to add an alarm. Then, in the
„Sensor“
item, select the sensor whose alarm limit you want to set.
2.
Enable an Alarm
Using the
„3D button“
, select
„Enabled“
and press to enable the
alarm and display the alarm parameters.
3.
Parameter Values
„Condition“
defines the condition which must be met in order to
trigger the alarm. The value
„X“
will vary with the sensor being used.
4.
File
This item allows you to select the audio file that is played when the
alarm occurs. Press
„F1“
to play the selected audio file. Press
„F2“
to
stop playing the selected audio file.
5.
Activation Switch
If the switch is assigned, the alarm is enabled or disabled according
to the switch status.
6.
Repeat
If the alarm condition occurrence is longer than the selected audio
file, you can use this item to repeat the audio file. If a check mark is
displayed then the audio file will repeat. If an "x“ is displayed then the
audio file will play only once.
7.
Announce current value by voice
EX Alarms provide the ability to tell you the actual value of a given
sensor’s variable. If you want the alarm value to be announced, then
check this option.
4.
4.
8.
Set Throttle Idle
With this item activated, you model’s throttle will go to idle when the
alarm condition occurrs.
9.
Use only during preflight check
You can use any alarm to be a part of a preflight control check. As an
example, create a new low-voltage alarm (a voltage sensor is
required). If you use 4S Li-Pol battery, the alarm condition should be
"X<16V" (less than 4V per cell). Enable the "Use only during preflight
check" option. This alarm will activate only after the model is
changed or the transmitter is turned ON.
From this moment on, you will always be notified when you plug in a
partially discharged battery by mistake. An informative window will
pop up over the main screen within a regular period. The alarm will
sound until you either insert another, fully charged battery, or you
press the "F(3)" Cross button in the informative window to cancel the
preflight alarms entirely.
10.
Vibrations
For each alarm you can optionally specify a type of vibrations (1-3
pulses, long or short) .
106
Summary of Contents for Jeti DS-12
Page 2: ...computer radio control system EN...
Page 8: ...computer radio control system EN 8...
Page 51: ...computer radio control system EN 3 3 51...
Page 147: ...computer radio control system EN...
Page 148: ...computer radio control system EN...
Page 149: ...computer radio control system EN...
Page 150: ...computer radio control system EN...
Page 151: ...computer radio control system EN JETI model s r o Lomen 1530 742 58 P bor www jetimodel com...