Version 08.2017 | Page/ Seite 7
www.dunkermotoren.com
Chapter 2
Installation
UNPACKING
• Check packaging for signs of damage.
• Remove packaging. Do not discard. In the event of items requiring return, it is recommended that the original
packaging be used.
• Metal surfaces may be hot or below 0
o
C following prolonged storage.
•
Ensure that the delivery note correctly reflects your order and the items delivered.
• Check equipment for signs of damage. Never use the equipment if it appears damaged in any way.
• Read the User Guide before installing and using this equipment.
INSTALLATION
Intended operating environment
This equipment is intended for use in an environment within the following conditions:
Operating temperature
0 to +40 °C
Storage temperature
-25 °C to +70
°C
Altitude (above mean sea
level)
1000 m
Overvoltage category
II
Pollution degree
2
EMC
light industrial
Mechanical
Mounting module to user’s surface
All torque figures are non lubricated i.e. no thread lock.
For all modules, ensure that the mounting surface is as flat as possible. The module can be mounted by two methods:
•
Using the system clamp top fixings. Both sides should be clamped with a distance between clamp centres of no
more than 100 mm. Each M4 bolt should be tightened to a torque of 4 Nm.
• Using the M4 T-nut slots on the underside of the module. This requires access from underneath the mounting
surface. Both sides should be fixed with a distance between fixing centres of no more than 100 mm. Each M4
bolt should be tightened to a torque of 4 Nm.
Mounting user’s payload to module moving forcer
The payload is mounted to the moving forcer top surface using the M3 clearance holes.