THRUST ROD
One of two types of thrust rod end supports are fitted to the module. If the thrust rod end supports
fitted are as shown right, it is not recommended that thrust rod replacement is attempted. In this
case the complete module must be returned to the supplier for replacement to be carried out. For
the type of thrust rod support shown in Figure 3.5, carry out the following procedure.
Removal
• Move the forcer to the centre of the module, Figure 3.5.
Forcer
position forcer to
centre of module
Figure 3.5
• Place spacers around or under the thrust rod to prevent it coming into contact with the bearing rail or other
ferrous material. Foam pipe insulation or wooden blocks are ideal for this.
•
Loosen the two M4 bolts on each of the thrust rod end supports, see Figure 3.6.
WARNING.
If people with Pacemaker work with this equipment, the Pacemaker could interfere or fail.
» People with Pacemakers or metal implants must not handle or work with the thrust rod
CAUTION.
Thrust Rod contains powerful magnetic components and must be handled with care. If you do
not follow the instructions below, it may cause personal injury, such as bruises, up to amputation of limbs
(e.g. fingers).
» Only handle one rod at a time
» Never remove safety sleeving if not absolutely necessary, and handle/transport the thrust rods
in the original packaging
» Never use thrust rod, if it appears damaged
CAUTION.
The linear modules can be particularly heavy and can not be lifted alone.
» Lift linear modules always together with another person
NOTICE.
The magnetic field from the thrust rod can damage magnetic media and credit cards when in
close proximity.
» Keep away any magnetic media and credit cards from the thrust rod