OVER-TEMPERATURE SENSOR
CAUTION. It is strongly recommended that the forcer over-temperature sensor is connected to
the drive amplifier or servo controller
at all times in order to reduce the risk of damage to the
forcer due to excessive temperatures.
OPTIONAL ENCODER
If an additional encoder (Renishaw) has been supplied, there will be a third cable to connect to the amplifier. The
Renishaw encoder cable is terminated in 9-pin D-type plug. An adaptor cable is supplied to allow the sensor to
connect to the amplifier at connector J5.
CONNECTING TO AN AMPLIFIER
Connection details to the Accelnet Micro Panel Amplifier are shown in the diagram below.
TO J4
TO J5
TO J2
POWER CABLE
OPTIONAL
ENCODER CABLE
SENSOR CABLE
ACCELNET
MICRO PANEL
J2
J5
J4
Black (LOAD)
Blue (0V)
NPN
Brown (+V)
Black (LOAD)
Blue (0V)
PNP
LOAD
Brown (+V)
LOAD