Version 08.2017 | Page/ Seite 29
www.dunkermotoren.com
SPECIFICATION
VALUE
UNITS
Output signal period
25.6
mm
Signal amplitude (b/-
signals)
1
Vpk-pk
Output current
± 10
mA
Supply voltage
5 ± 0.25
Vd.c.
Supply current (output current=0)
32 ± 5
mA
Resolution
(1)
8
micron
Position repeatability
(2)
± 12
micron
Absolute accuracy
(3)
± 350
micron
Notes:
(1)
Dependent on amplifier
(2)
Dependent on amplifier. Under constant operating conditions. Self-heating of the forcer will cause expansion
in the thrust rod during the initial warm up period. In high duty applications (corresponding to an internal
forcer temperature of 80
o
C) a 1 metre thrust rod will expand typically by 250 µm.
(3)
Maximum error over 1 metre under constant operating conditions.
FORCER ELECTRICAL CONNECTIONS
Connections to the forcer are made via a 15-way high density D-sub male connector which is fitted to the forcer.
The pin-outs are shown in the diagram below and the table shown right.
PIN NUMBER FUNCTION
1
+SIN
2
-SIN
3
+COS
4
-COS
5
+5Vd.c.
6
0V
7
+TH (Thermistor)
8
-TH (Thermistor)
9
Factory use only
10
Factory use only
11
No connection
12
Earth (forcer body)
13
Forcer phase U
14
Forcer phase V
15
Forcer phase W
Connector
body
SCREEN