Appendix E: Network Protection
Installation Instructions
IMPORTANT!
The following requirements for installation of CAT5 ethernet cable must be observed for correct
operation of connected equipment.
Do
NOT
strip off cable sheathing more than required for proper termination.
Do
NOT
kink or knot cable.
Do
NOT
crush cable with cable ties.
Do
NOT
splice cable.
Do
NOT
bend cable at right angles or make any other sharp bends.
Note:
All cable bends must have a minimum 2" (50mm.) radius.
Do
NOT
untwist CAT5 pairs more than ½” (12mm).
Do
NOT
exceed maximum 6” (150mm.) from center of ferrite to T-Link Network Connector
INSTALLATION of CAT-5 Ethernet Cable
NOTE:
I
nstall the ferrite inside the control
panel as close to the T-Link network
connector as allowable.
6” (150 mm.) max from center of ferrite to
the network connector).
INSTALLATION of RJ-45 to RJ-45 Mounting Plate
(CE Installations Only)
Drilling Template
Installation:
1.
Remove the knockout located on the
top right hand side of the cabinet.
2.
Drill 2 holes in cabinet location using
the drill template and 2.5mm (3/16”)
drill bit.
3.
Secure the mounting plate externally
to the cabinet using the #6 Type F,
self-tapping screws provided.
4.
Connect RJ-45 cables observing the
“Important” notice indicated above.
5.
Verify operation.
CAT5 Ethernet Cable
Ferrite
DSC PN 10000089
To T-Link
Network
Connector
To Network