22
[062] Fire On Time
Default:
05
The Bell Pulse On Time is used with Digital Input#1 when configured for Bell Follower mode.
The Bell Pulse On/Off Time is the time of the pulse width. This option is programmed in hex
times 100 milliseconds.
[063] Fire Off Time
Default:
05
The Bell Steady On Time is used with Digital Input #1 when configured for Bell Follower mode.
This is the minimum time in 100ms increments that the bell must be active/sounding before it
will be considered a steady on state and generate the Burglary Alarms. This option is pro-
grammed in hex times 100 milliseconds.
[064] Restoral Delay Time
Default:
64
The Restoral Delay Time is used with Digital Input#1 when configured for Bell Follower mode.
It is the minimum time that the bell must be inactive before it will be considered a Fire/Burglary
Restoral.
[065] Fire Pulse Count
Default:
03
The Fire Pulse Count is used with Digital Input #1 when configured for Bell Follower mode.
The pulsed count will be the minimum number of pulses (high and low forming 1 cycle) before
the T-Link will consider it an alarm state.
[066] SIA ACK Time
Default:
02
The SIA ACK Time option is the maximum wait time (seconds) for a response from a receiver
for any messages sent to the receiver.
[067] DVACS Account Number
Default:
00
The T-Link TL250 will use this number to receive DVACS signals from the control panel and to
supervise the panel.
[068] DVACS Extended
Default:
01
The SG-DV1660LC software versions 3.00 and higher support the group arm/disarm option. If a
value other than ‘00’ is programmed here, the T-Link TL250 will poll the subscriber’s control
unit repeatedly to get the transmitter group number arm/disarm status change and the user
number. This information is combined then sent to the receiver. This allows the automation
software to keep track of partition arm/disarm status. Program ‘01’ to enable or ‘00’ to disable
this option.