WatchMaster
®
IP Elite User Manual
13
4.
Attach one open end wrench onto the flange of the cable gland and tighten the compression
nut, with the second open wrench, to approximately 50-55 in-lbs. of torque.
5.
Assemble a new RJ45 head to the Cat 5 Ethernet Cable.
6.
Assemble a mating power connector to the 2 AC or 2 DC power cables.
Figure 9: IP66 with Ethernet and AC/DC Power
Securing for IP66 (Analog & AC/DC Power – IP Elite 3000 Only)
1.
Slide the Coax cable through the threaded end of the cable sealing gland, with Orange O-
Ring installed.
2.
Slide the 2, 20 AWG power wires (and any RS-485 wires) through the back side of the
cable sealing gland.
3.
Measure approximately 4.5 inches of cable slack from the end of the cable to the rubber
grommet of the sealing gland. Use a scale to measure the length.
4.
Attach one open end wrench onto the flange of the cable gland and tighten the compression
nut, with the second open wrench, to approximately 50-55 in-lbs. of torque.
5.
Assemble a new RJ45 head to the Cat 5 Ethernet Cable.
6.
Assemble a mating power connector to the 2 AC or 2 DC power cables (and RS-485 cables
if used).
For All Configurations
1.
Pull the cable(s) taut back through the IP Camera, exposing the thread of the cable sealing
gland out of the base of the IP Camera.
2.
Assemble the Electrical Nut back onto the gland and tighten the Nut securely until it is
finger tight. Use the Hex wrench to tighten the electrical nut to approximately 8 in-lbs. of
torque.