Specifications and References
Physical and Operational Specifications
A-3
Table 10
Power Supply
Taken from 4-20mA control signal
Compliance Voltage Rating
9.0 Volts at 20 mA, 11.0 Volts at 4.0 ma
Minimum Current Signal to Start Up
3.2 mA
Minimum Input Span for Split Range Operation
5mA
Upper Range Value for Split Range Operation
Between 8 and 20 mA
Lower Range Value for Split Range Operation
Between 4 and 14 mA
Minimum/Maximum Wire Size
14/28 AWG
Strip Length
0.22 in / 6 mm
DIgital Communication
HART Communication protocol signal from ValVue software on a
personal computer or a hand held device. HART point to point
and burst mode.
Local Display Liquid Crystal (optional)
Three lines of nine alpha numeric characters
Push Buttons
Three Explosion Proof / Flameproof push buttons
Input Signal, Power, and Display Specifications
Table 11 Construction Material Specifications
Housing and Cover
Aluminum ASTM B85 SC84B standard
Stainless Steel optional
Weight
Standard - 7.4 lbs./ 3.357 kg
Stainless Steel - 16 lbs/ 7.257 kg
Relay and Manifold
Single Acting - PPS, 300 Series Stainless Steel, nitrile diaphragms
Double Acting - 300 Series Stainless Steel, Ryton
Aluminum 6061 T6, Ryton
I/P Motor
430 stainless steel, PPS, 300 series stainless steel
Mounting Bracket
300 series stainless steel
Magnet Holder
Corrosion Protected Anodized Aluminum 6061 T6
Pole Ring
416 stainless steel
Levers
300 Series stainless steel