After Use
36
После использования
●
The
last residual pressure warning
is generated when the pressure
reaches to approx. 10 bar.
Alarm:
Intermittent bleep,
continuous
Red LEDs:
Flash constantly.
Approx. 95 % of the oxygen in the
cylinder have now been consumed.
After Use
●
Unplug the breathing hoses from the
mask:
1
Press the button and
2
pull out the plug-in coupling.
●
Immediately after pull out the plug-in
coupling close the cylinder valve.
●
The air is automatically let out of the
breathing circuit.
Switching Off Bodyguard
●
Simultaneously press the right and
left hand button until a single sharp
audible "Bleep" sounds.
●
Release buttons.
— For 3 seconds Bodyguard shows the
battery status.
— Bodyguard switches off.
DANGER
The mission must be ended and
PSS BG 4 taken off when the pressure
reaches 10 bar.
This must be done in a safe environ-
ment (see “Use” on page 31).
11
52
1
50
7
.eps
bar
04
7
2
1
5
0
7
.eps
1
2
11
3
2
1
5
0
7
.e
p
s
bar
1x Bleep
bar
0462
1
50
7
.eps
●
Последний предупредительный
сигнал о низком остаточном
давлении
подается, когда
давление достигает примерно
10 бар.
Сигнал:
Прерывистый
звуковой сигнал,
непрерывный
Красные СД:
Непрерывно
мигают.
К этому моменту израсходовано
приблизительно 95 %
кислорода в баллоне.
После
использования
●
Отсоедините дыхательные шланги
от маски:
1
Нажмите кнопку и
2
выньте штекерный соединитель.
●
Немедленно после того, вынут
штекерный соединитель, закройте
вентиль баллона.
●
Воздух автоматически стравится
из дыхательного контура.
Выключение Bodyguard
●
Одновременно нажмите и
удерживайте правую и левую
кнопки, пока прибор не подаст
однократный резкий звуковой
сигнал.
●
Отпустите кнопки.
–
В течение 3-х секунд Bodyguard
показывает состояние батареи.
–
Bodyguard выключается.
ОПАСНО
Закончите работы и снимите
PSS BG 4, когда давление упадет
до 10 бар.
Это должно выполняться в
безопасной среде (см.
"Использование" на стр. 31).