26
Remote Operation
Example
SYST:ERR?”
Result was “4, SYNTAX ERROR”, check for more errors.
Description: There is a misspelling in the command or a non-numeric
character was included in a command where a number should have been,
or use of unrecognized symbols such as %, &, #, etc.
SYST:ERR?”
Result was “5, DATA OUT OF RANGE”, check for more errors.
Description: The value transmitted is not acceptable.
Eg. 1: A non existing switch positions has been commanded. Sending
Route:Switch1 8
. When switch 1 is a SP6T (6 position switch)
Eg. 2: This error code is set if the IP address or MAC address is an invalid
one. Sending SYSTEM:IPADDRESS 55.57.2 would generate this error
code since 4 numbers are required for a valid IP address.
SYST:ERR?”
Result was “10, SWITCH DID NOT RESPOND,x”, check for more errors.
Description: Switch x did not respond to a position query.
E.g. communication failure or damaged switch.
SYST:ERR?”
Result was “11, SWITCH’S RESPONSE INVALID,x”, check for more errors.
Description: Switch x responded but with the wrong response code. This
error is related to wrong internal communication codes.
SYST:ERR?”
Result was “12, SWITCH’S POSITION INCORRECT,x”, check for more errors.
Description: Switch x reported to be closed on a position different than
what it was commanded to be.
E.g. Commanded position is 4, reported position is 3.
SYST:ERR?”
Result was “13, SWITCH’S POSITION UNKNOWN,x”, check for more errors.
Description: Switch x reported to be closed on an unknown position. E.g.
A defective / damaged switch.
SYST:ERR?”
Result was “20, MINI-MATRIX IS NOT CONFIGURED”, check for more errors.
Description: The configuration file (factory configuration) defining all
switches configured inside the Mini-Matrix has not been uploaded. The
Mini-
Matrix does not ‘know’ what and how many switches to control.