50
Web Page Server
7.5 The Sequencer
Clicking on “
Sequencer
” will show the page below.
The sequencer allows for many commands (steps) to be implemented, and
exectued in sequential order. The user has control over each switch, the
position of each switch, and the delay in milliseconds (minimum 50ms) between
each command (step). The sequencer can handle up to 500 commands (steps)
that can be added or deleted by the user. A step can be added by choosing the
step number, switch to be commanded, position of the switch, delay of the step,
and then
clicking ‘
Insert
’. A step can be deleted by typing a step number into the
box next to ‘
Step:
’, and then clicking ‘
delete
’. A step can be edited by using the
‘
Change
’ button. The ‘
Clear
’ button will clear all of the steps in the sequencer
program. The user has the option to make and save up to 10 sequencer
programs.
The drop down menu at the top of the page next to ‘
Sequencer#
’
shows which
sequencer program is currently being used. The ‘
Run
’, ‘
Pause
’,
and ‘
Stop
’ buttons allow the user more control over the sequencer. There is an
option to loop the sequencer program. To do this type the number of loops the
sequencer program should execute
in the box next to ‘
Loop:
’, and click ‘
Loop
’.
The sequencer also has a log. It can be diasbled if it is unneccessary by clicking
‘
Disable Log
’, or it can be viewed by clicking ‘
View Log
’. For more on the ‘
Log
’
read section 7.6. There is
an ‘
Error
’ button at the bottom of the page that will
turn red if an error occurs. Clicking on the ‘
Error
’ button will take the user to the
control page and display the error.