45
Remote Operation
Note:
1. Commands are
NOT
case sensitive.
2. Every command and response on the serial or USB port shall
have “\r\n” Carriage return
(0x0D) and Line Feed (0x0A) at the end.
3. Multiple commands with same header can be given in a single command line. (See rule # 5
for an exception to this).
e.g. SYST:IPADDRESS?;TCPPORT?;SERIALNUMBER? or ROUTE:SWITCH1
2;SWITCH1?;
note that the commands have to separated by ‘
;
’
4. The default settings for the Ethernet interface are:
a. IP Address: 10.180.50.233 (DHCP = OFF)
b. TCP/IP Port number: 10
c. Gateway address: 10.180.50.1
d. Subnet mask: 255.255.255.0
e. Serial number: 65535
f.
In command SYST:TIMEOUT? The returned value n is in seconds. The default value
is 0. 0 = no timeout.
5. Command numbers followed by a * require a system reboot to become effective.