![Dover Tipper Tie RS4203 User Manual Download Page 44](http://html1.mh-extra.com/html/dover/tipper-tie-rs4203/tipper-tie-rs4203_user-manual_2524921044.webp)
RS4203 Operating Manual
Chapter 7 - Recipe Descriptions
Rev 32, 01/11/13
Copyright © 2013, Tipper Tie, Inc., All rights reserved
44
Item
Operating
Parameters/Features
Description
Valid Range
Default
8 PIECES/SHIRR (COUNTER) Used to enable the pieces/shirr counter.
On or Off
Off
9 PUNCH CUSHION (ON/OFF)
If OFF, allows the punch to extend more
quickly. If ON, provides an air cushion to
slow the extension of the punch. More
fragile casings may require the cushion.
On or Off
On
10 STRING LOOPER (ON/OFF) Turns the STRING LOOPER ON or OFF
On or Off
Off
11
CONTINUOUS LOOPS
(ON/OFF)
Used to place a loop on every chub
regardless of knife cycle. (Looper must
also be “ON”).
On or Off
Off
12 TRIP PADDLE (ON/OFF)
Turns the TRIP PADDLE ON or OFF.
When ON, the trip paddle initiates the clip
cycle.
On or Off
On
13 PORTION TIMER (ON/OFF)
Used to enable the 4203 internal portion
timer.
On or Off
Off
14 FILL LAG COMP (ON/OFF)
Turns The FILL LAG feature ON or OFF.
(FILL LAG COMPENSATE is used to
send the start signal to the filler, before
the voider plates fully retract. This allows
the operator to adjust the point in the clip
cycle when the product begins to flow.
The FILL LAG COMPENSATE “time”
should initially be set at a large value and
gradually decreased until the desired
Filler start timing is reached.)
On or Off
Off
15
SKIN BRAKE FWRD
(ON/OFF)
If “ON” locks the skin brake in the forward
(or fill position).
On or Off
Off
16 SKIN BRAKE LAG (ON/OFF)
If “ON” causes the skin brake to move to
the clip position AFTER the voiders have
closed. If “OFF” the skin brake will move
to the clip position as the voiders are
closing.
On or Off
Off
17 REGISTRATION (ON/OFF)
Enables registration software, which
enables the registration sensor to sense
and detect the Indicator mark and
subsequently initiate the clip cycle. Trip
Paddle must also be ON, since the
sensor waits for the trip paddle to begin
Indicator mark detection scan.
On or Off
Off
18
PNEUMATIC
FILLER(ON/OFF)
Enables a pneumatic output which cycles
at the same time as the electronic filler
output.
On or Off
Off