background image

Revisions M1040-ANT

Revision #

ECO

Effective

Software Version

Key Changes

0

1966

10/15/2021

Initial Release

NOTE:

It is possible that older software versions might not support all features

Installation Manual - Revision: 0 - DRAFT | Dover Fueling Solutions

26

Summary of Contents for Petro Vend M1040-ANT

Page 1: ...Installation Manual Part Number M1040 ANT Revision 0 Automatic Vehicle Identification Antenna ...

Page 2: ...OLUTIONS and other trademarks referenced herein are trademarks of Delaware Capital Formation Inc Dover Corporation Dover Fueling Solutions UK Ltd and their affiliated entities Contact OPW Fuel Management Systems Visit us at https www doverfuelingsolutions com or contact us at Call 1 877 OPW TECH 877 679 8324 For calls outside US and Canada call 1 708 485 4200 Monday through Friday 7 a m to 6 p m U...

Page 3: ...omplete the Installation 15 2 3 1 Omni Antenna Installation Scenario Terminal VIS 16 2 4 Remote Installation 16 2 4 1 Omni Antenna Installation Scenario Remote VIS 16 Section 3 Panel Antenna 17 3 1 Components 17 3 2 Terminal Installation 17 3 2 1 Install the Flange 18 3 2 2 Assemble the Antenna and Bracket 19 3 2 3 Cable Routing 21 3 2 3 1 Cable Routing Outside the Pole 22 3 2 3 2 Cable Routing In...

Page 4: ...2 Panel Antenna Canopy Installation Scenario Terminal VIS 24 3 4 Remote Installation 25 3 4 1 Panel Antenna Installation Scenario Remote VIS 25 Installation Manual Revision 0 DRAFT Dover Fueling Solutions 4 ...

Page 5: ... avoid the possibility of explosion or fire when you install these components near the Hazardous Area use pneumatic tools only Be sure your system is completely de energized before you do the installation DANGER Make sure that the pole used to install the antenna is not grounded to the terminal or other system components Make sure the antenna is isolated from the pole Use a non conductive material...

Page 6: ...containers that can release hazardous vapors from flammable liquids or gases n A failure or incorrect operation of positive mechanical ventilation precautions result in the release of hazardous concentrations of flammable gases or vapors n Concentrations of flammable gases or vapors can occasionally flow from a containment or ventilation system to an adjacent Class I Division 1 location This flow ...

Page 7: ...recommended to do a check of the electrical system with a multimeter to make sure all connections are de energized before you proceed with the installation Installation Manual Revision 0 DRAFT Dover Fueling Solutions 7 ...

Page 8: ...installed VIS or remote VIS for optimum antenna performance 2 1 Components The Omni Antenna kit OPW FMS P N 20 4502 1 has these components l Antenna base stem assembly tool and 12 cable OPW FMS P N 75 3067 l Bracket OPW FMS P N 51 0589 l Cable Gland OPW FMS P N 50 0567 Installation Manual Revision 0 DRAFT Dover Fueling Solutions 8 ...

Page 9: ...ge and pole are recommended NOTE If the pole needs additional support it can be clamped to a nearby support or structure DO NOT clamp the pole to the pedestal or terminal 2 2 1 Install the Flange DANGER Do not use electric or battery operated power tools To avoid the possibility of explosion or fire when you install these components near the Hazardous Area use pneumatic tools only Be sure your sys...

Page 10: ...fasteners for the material where the flange is installed 2 2 2 Assemble and Install the Antenna 1 Put the antenna stem over the threaded post of the base and turn clockwise to tighten Be sure that the stem is flush with the bottom of the post Installation Manual Revision 0 DRAFT Dover Fueling Solutions 10 ...

Page 11: ...2 Put the right angle connector of the cable through the center hole of the long part of the bracket Installation Manual Revision 0 DRAFT Dover Fueling Solutions 11 ...

Page 12: ...hown above Use the plastic assembly tool that was included in the kit to tighten the antenna to the connector 4 Install the clamps through the cut outs in the bracket as shown above Installation Manual Revision 0 DRAFT Dover Fueling Solutions 12 ...

Page 13: ...as shown above and tighten the clamps 6 Install the pole into the flange Turn the pole clockwise until the pole is almost to the end of the threads and the antenna points in the correct direction Installation Manual Revision 0 DRAFT Dover Fueling Solutions 13 ...

Page 14: ... terminal enclosure 2 2 3 Cable Routing The Antenna Cable can be attached to the outside of the pole or put through the inside of the pole 2 2 3 1 Cable Routing Outside the Pole As an alternative the cable routing can go outside the pole l Use cable ties at regular intervals to attach the cable to the outside of the pole Installation Manual Revision 0 DRAFT Dover Fueling Solutions 14 ...

Page 15: ... the SMA connector end of the cable through the top of the pole and through the Exit Port 4 Use a silicone sealant to seal the Entry Port in the cap in the top of the pole and the Exit Port after the connections are made 2 3 Complete the Installation 1 Install the cable through the Cable Gland 2 Connect the SMA connector to the Antenna Connector of the AVI board in the terminal 3 Connect the 20 17...

Page 16: ...install the Remote VIS refer to M00 20 8225 AVI 2 4 1 Omni Antenna Installation Scenario Remote VIS For maximum antenna range install the antenna a minimum of 12 feet from ground level The remote VIS enclosure should be installed at eye level Installation Manual Revision 0 DRAFT Dover Fueling Solutions 16 ...

Page 17: ...et l 15 Cable OPW FMS P N 12 1305 l Cable Gland OPW FMS P N 50 0567 3 2 Terminal Installation To install the Panel Antenna at the terminal with a terminal installed VIS you will need l 2 diameter x 12 length minimum pole galvanized or aluminum One end must be threaded to fit the threads of the flange IMPORTANT Do not use cable extensions Use of a cable extension can have an unwanted effect on the ...

Page 18: ...installation DANGER Make sure that the pole used to install the antenna is not grounded to the terminal or other system components Make sure the antenna is isolated from the pole Use a non conductive material between the antenna bracket and the metal pole l Install the flange so the pole will be close to the left side of the pedestal Use the correct bit and fasteners for the material where the fla...

Page 19: ...ign the four 4 holes as shown in the illustration above with the four 4 threaded inserts on the back of the antenna n Put a Flat Washer and Lock Washer over each hole n Put a short Hex Cap Screw into each hole and tighten the screws 2 Assemble the Pole Wall Mount MNT 22 3 to the Angle Bracket MNT 22 2 n Align the two parts so that their toothed surfaces point to each other and the holes are aligne...

Page 20: ...et MNT 22 4 to the Pole Wall Mount MNT 22 3 v Put a Flat Washer and Lock Washer over the two 2 inside screw holes of the Pole Bracket v Put a 5 16 18 x 5 Hex Cap Screw through both holes and through the two 2 inside screw holes of the Pole Wall Mount v Put a 5 16 18 Hex Nut onto the end of both screws and tighten them n Adjust the antenna angle for best performance v Loosen the nut slightly for th...

Page 21: ...ll the pole into the flange Turn the pole clockwise until the pole is almost to the end of the threads and the antenna points in the correct direction l Install the Cable Gland into the terminal Use a 3 4 punch to open the knockout on the top of the terminal Make sure the rubber seal is under the top nut and is tight enough to keep moisture out of the terminal enclosure 3 2 3 Cable Routing The Ant...

Page 22: ...utside the Pole As an alternative the cable routing can go outside the pole l Use cable ties at regular intervals to attach the cable to the outside of the pole Installation Manual Revision 0 DRAFT Dover Fueling Solutions 22 ...

Page 23: ... the SMA connector end of the cable through the top of the pole and through the Exit Port 4 Use a silicone sealant to seal the Entry Port in the cap in the top of the pole and the Exit Port after the connections are made 3 3 Complete the Installation 1 Install the cable through the Cable Gland 2 Connect the SMA connector to the Antenna Connector of the AVI board in the terminal 3 Connect the 20 17...

Page 24: ... 3 3 2 Panel Antenna Canopy Installation Scenario Terminal VIS The Panel Antenna can be installed under a canopy The cable can beinstalled to a terminal installed VIS or a Remote VIS enclosure Installation Manual Revision 0 DRAFT Dover Fueling Solutions 24 ...

Page 25: ...f the Remote VIS enclosure 3 4 1 Panel Antenna Installation Scenario Remote VIS Install the Panel Antenna on a wall with fasteners applicable for the material where the antenna will be installed For instructions on how to assemble and install the supplied antenna bracket go to the manufacture s site at https mars antennas com product mnt 22 For maximum antenna range install the antenna at approxim...

Page 26: ...sion ECO Effective Software Version Key Changes 0 1966 10 15 2021 Initial Release NOTE It is possible that older software versions might not support all features Installation Manual Revision 0 DRAFT Dover Fueling Solutions 26 ...