Access rights
Technical Manual
50
V28 - 08/2019
Electronic safe lock
Menu
Function
Authorized codes (config-
ured with input unit, ex fac-
tory)
Description
MA
Mx
U
C
MISC
Activating or deactivating
Code Denial Bank Mode
GROUP 4 (off/on)
-
-
The Manager 4 is
only able to activate
or deactivate user
group 4.
When Code Denial
is set to "on", the
codes of user group
4 will be deacti-
vated.
MISC
Activating or deactivating
the Duress Code in Bank
Mode
DURESS bank (off/on)
-
-
-
MISC
Activating or deactivating
One Shot Codes in Bank
Mode
ONE SC4 bank (off/on)
-
-
-
It is possible to acti-
vate One Shot
Codes with user
group 4.
The Manager 4 will
not be deleted when
entering the Man-
ager Code 40 and
the function One
Shot Codes is acti-
vated.
MISC
Activating or deactivating
the Time Lock in OTM
TL LOCK cit (off/on)
-
-
-
MISC
Displaying the current
time in OTM
TIME cit (off/on)
-
-
-
If 'Time cit is set to
"on", the current
time will be dis-
played.
If 'Time cit is set to
"off", "IDENTIF"
will be displayed.
MISC
Setting the Wake Up
Mode in Mixed Mode
WAKE UP (bank/cit)
-
-
-
MISC
Setting the function
Freeze
FREEZE (off/on)
-
-
-
It is only possible to
set the function
Freeze with the
master lock.
Resetting the battery
message "BAT-CMP
open"
-
-
The Master or a
Manager Code must
be entered to reset
the battery mes-
sage.
Reading Audits in AS284-
USBW or AS284-NETW
-
-
-
The Master Code
must be entered in
AS284-USBW or
AS284-NETW to
read an Audit.